Badger Meter Inc HREBT Manual De Usuario

Descargar
Página de 12
Crimp the Gel-Connector using the Crimping Tool making sure the 
plunger is fully seated so there is no visual gap between the cap’on 
the plunger and the shell of the Gel-Connector.
Gel connector in the crimping tool
Proper crimp—plunger fully seated
Inspect the Gel-Connector to insure that the conductors did not 
back out during crimping and that the Gel-Connector plunger is 
fully seated.
Plunger is fully seated
Conductor is all the way through
Conductors are still all the way through to the end of the  
Gel-Connector and the plunger is fully seated.
Repeat this procedure for the remaining like color conductors.
If the wire is cut or broken and requires a field splice after initial 
installation, connect like colors to maintain proper installation.
PIT INSTALLATIONS
Insert the entire splice assembly into the filled splice tube  
P/N 62085-001 as indicated in the figure below. Close the cover  
with leads exiting alternate sides as indicated in Figure 2.
Figure 2: Splice enclosure assembly
HRE WITH TERMINAL SCREWS
OTEE:
N
The HRE with optional terminal screws is suitable for indoor 
installation only.
The terminal screws are identified by the letters “R”, “B”, and “G” 
(standing for Red, Black, and Green) molded into the screw cavity.
Strip approximately 1-1/2" of outer insulation sheath using the  
59989-001 coax stripping tool. Use caution in removing the outer 
sheath so that the inner wire insulation is not damaged.
Unwind the outer foil shield from the cable and cut it off even with 
the outer sheath using the wire cutting pliers. Cut the uninsulated 
shield drain wire even with the outer sheath.
Strip approximately 1/2" of insulation from the inner wires using the 
59993-001 wire stripper. Use a screwdriver to loosen the terminal 
screws sufficiently to allow the bare wire ends to fit below the screw 
heads. Bend the bare wire ends into hook shapes that will closely fit 
around the shafts of the terminal screws, and hold the hooks around 
the screw shafts while tightening the screws with the screwdriver. 
Do not overtighten screws. The hooks should be oriented with the 
openings to the right, so that tightening the screws (by turning to 
the right) will tend to draw the wire closer to the screw.
Place plastic cable tie P/N 34776-001 approximately 1/4" from end 
of outer insulation sheath. Tighten securely for strain relief. Remove 
excess cable tie. Ensure that the cable exits the terminal screw cavity 
via the opening on the right side of the cavity wall and that cable 
tie resides on interior of terminal cover. Place the cover over the 
terminal screw cavity and secure by tightening the Torx screw.
TESTING
After connections are complete, test the entire installation including 
the HRE, wiring, and remote or pit module for proper operation in 
accordance with the instructions supplied with the module.
Install the HRE on the water meter and secure it using the Torx  
screw provided.
LICENSE REQUIREMENTS
This device complies with Part 15 of the FCC Rules. Operation of 
this device is subject to the following two conditions: (1) This device 
may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause 
undesired operation. Any changes made by the user not approved 
by Badger Meter can void the user’s authority to operate the 
equipment. No license is required by the utility to operate an HRE 
meter reading system.
www.badgermeter.com
ADE, BadgerTouch, Recordall, and RTR are registered trademarks of Badger Meter, inc. Other trademarks appearing in this document are the property of their respective entities. 
Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the 
extent an outstanding contractual obligation exists. © 2013 Badger Meter, Inc. All rights reserved. 
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836 
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 
This device complies with Industry Canada licence-exempt RSS standard(s). 
Operation is subject to the following two conditions: (1) this device may 
not cause interference, and (2) this device must accept any interference, 
including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables 
aux appareils radio exempts de licence. L'exploitation est autorisée aux 
deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, 
et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique 
subi, même si le brouillage est susceptible d'en compromettre le 
fonctionnement.