Climax Technology Co Ltd CTC1052RV Manual De Usuario
29
Center.
<
<
N
N
O
O
T
T
E
E
>
>
)
This function is for WTR- Series only,
not for WTRV.
not for WTRV.
4.6. Factory Reset
CTC-1052RV will clear all programmed
parameters by the following sequence:
parameters by the following sequence:
Step 1. Unplug the power cord from the DC
Jack.
Step 2. Remove the Battery Switch rubber
cap.
Step 3. Use a pen or screw-driver to slide the
Battery Switch to OFF position (or the
opposite direction of the ON marking)
opposite direction of the ON marking)
Step 4. Plug the power cord into the DC jack
while holding down both the HELP &
RESET buttons, until one long beep
is heard, indicating that the Factory
Reset is successful.
RESET buttons, until one long beep
is heard, indicating that the Factory
Reset is successful.
Step 5. Release both buttons.
Step 6. Slide the Battery Switch back to ON
position again.
Step 7. Replace the Battery Switch rubber
cap.
<
<
N
N
O
O
T
T
E
E
>
>
)
Once the Fatory Reset is executed, all
the programmed data is returned to its
default value and all the devices that
have been learnt-in are removed. You
will have to do the programming and
learn-in the devices one-by-one again.
default value and all the devices that
have been learnt-in are removed. You
will have to do the programming and
learn-in the devices one-by-one again.
5. Appendix
5.1. CID Event Code
z
100 - Panel emergency
When the red HELP Panel button is
pressed.
pressed.
z
101 - Personal emergency
When the Wrist Transmitter (WTR),
Emergency Pendant or Fall Sensor is
pressed.
Emergency Pendant or Fall Sensor is
pressed.
z
102 –Inactivity
If no sudden movement within 10
seconds after fall detection, an
inactivity code will be sent to Central
Monitoring Station.
inactivity code will be sent to Central
Monitoring Station.
z
110 - Smoke emergency
When the Smoke Detector (SD) is
triggered.
triggered.
z
120 –Fall emergency
When a fall sensor is triggered.
z
147 - Sensor Supervisory Failure
When CTC-1052RV is unable to
receive the signal transmitted from the
Wrist Transmitter for a pre-set period
by Command #49, Green LED flashes
every 2 secs.
receive the signal transmitted from the
Wrist Transmitter for a pre-set period
by Command #49, Green LED flashes
every 2 secs.
z
154 - Water emergency
When Water Sensor (WS) is triggered
z
162 - Carbon Monoxide emergency
When Carbon Monoxide Detector
(CO) is triggered
z
301 - Panel AC Failure
When AC power fails for more than 10
sec, Green LED flashes every sec
with a beep every 30 secs.
sec, Green LED flashes every sec
with a beep every 30 secs.
z
302 - Panel Low battery
When CTC-1052RV is under Low
Battery status, Green LED flashes
every 2 secs with a beep every hour.
Battery status, Green LED flashes
every 2 secs with a beep every hour.
z
333 - No WTR Learnt-in
When CTC-1052RV has no WTRB
learned-in previously.
learned-in previously.
z
373 - Smoke Low battery
When Smoke Detector is under Low
Battery Status, Green LED flashes
Battery Status, Green LED flashes