Climax Technology Co Ltd CTC1052RV Manual De Usuario

Descargar
Página de 41
29 
Center. 
<
<
N
N
O
O
T
T
E
E
>
>
 
 
This function is for WTR- Series only, 
not for WTRV. 
 
4.6. Factory Reset 
CTC-1052RV will clear all programmed 
parameters by the following sequence: 
Step 1. Unplug the power cord from the DC 
Jack. 
Step 2.  Remove the Battery Switch rubber 
cap. 
Step 3.  Use a pen or screw-driver to slide the 
Battery Switch to OFF position (or the 
opposite direction of the ON marking) 
Step 4.  Plug the power cord into the DC jack 
while holding down both the HELP & 
RESET buttons, until one long beep 
is heard, indicating that the Factory 
Reset is successful.  
Step 5.  Release both buttons.  
Step 6.  Slide the Battery Switch back to ON 
position again. 
Step 7.  Replace the Battery Switch rubber 
cap. 
<
<
N
N
O
O
T
T
E
E
>
>
 
 
Once the Fatory Reset is executed, all 
the programmed data is returned to its 
default value and all the devices that 
have been learnt-in are removed.  You 
will have to do the programming and 
learn-in the devices one-by-one again. 
 
 
 
 
 
 
 
 
5. Appendix 
5.1. CID Event Code 
100 - Panel emergency 
‹ 
When the red HELP Panel button is 
pressed. 
101 - Personal emergency 
‹ 
When the Wrist Transmitter (WTR), 
Emergency Pendant or Fall Sensor is 
pressed. 
102 –Inactivity 
‹ If no sudden movement within 10 
seconds after fall detection, an 
inactivity code will be sent to Central 
Monitoring Station.   
110 - Smoke emergency 
‹ 
When the Smoke Detector (SD) is 
triggered. 
120 –Fall emergency 
‹ 
When a fall sensor is triggered. 
147 - Sensor Supervisory Failure 
‹ 
When CTC-1052RV is unable to 
receive the signal transmitted from the 
Wrist Transmitter for a pre-set period 
by Command #49, Green LED flashes 
every 2 secs. 
154 - Water emergency 
When Water Sensor (WS) is triggered 
162 - Carbon Monoxide emergency 
‹ 
 
When Carbon Monoxide Detector 
(CO) is triggered 
301 - Panel AC Failure 
‹ 
When AC power fails for more than 10 
sec, Green LED flashes every sec 
with a beep every 30 secs. 
302 - Panel Low battery 
‹ 
When CTC-1052RV is under Low 
Battery status, Green LED flashes 
every 2 secs with a beep every hour. 
333 - No WTR Learnt-in 
‹ 
When CTC-1052RV has no WTRB 
learned-in previously. 
373 - Smoke Low battery 
‹ 
When Smoke Detector is under Low 
Battery Status, Green LED flashes