GatesAir Inc. ULXATSC Manual De Usuario

Descargar
Página de 86
2-20
888-2715-001
2/19/10
 
WARNING: Disconnect primary power prior to servicing.
Section 2 Operation
Maxiva ULX ATSC Series
User Manual
2.9.1
System Faults
This screen is accessed by pressing the Faults button on the System screen. An active 
fault condition is highlighted in RED while a warning condition is highlighted in 
YELLOW.
For more information on these faults refer to Section 6, Diagnostics.
Figure 2-15  System Faults Screen
2.9.2
System Fault Log
This screen is accessed by pressing the System Fault Log button on the System screen 
in Figure 2-14 on page 2-19. It is a complete listing of all transmitter and system faults 
in the order in which they occurred. It can hold up to 99 faults and then becomes a FIFO 
(First IN - First Out) memory buffer, with the latest fault entry on topActive Faults 
will be highlighted and cannot be reset. All other faults will be cleared when the RESET 
button is pressed. Use the NEXT and PREVious buttons to view the entire list.
A complete listing of all faults which can show up in this log, along with a brief 
explanation of each fault, is given in the following tables in Section 6, Diagnostics.
• 
• 
•