WARNING: Disconnect primary power prior to servicing.
Section 3 Diagnostics
Maxiva ULX ATSC Series
User Manual
3.4
Fault Tables
The following tables provide a listing of Maxiva Transmitter faults along with a brief 
description, the fault level or threshold and the action taken by the transmitter.
Table 3-1  Maxiva Drive Chain Fault List
TYPE
Description
Fault Level or 
Threshold
Transmitter 
Action
Three 
Strike
Available 
in Life 
Support
IPA A Fault:  Power 
Supply, LDMOS, 
VSWR, Power 
Overload, Tempera-
ture, Input Power
The IPA can report 
up to 6 faults via 
their parallel con-
trol pins 
Any one fault active
IPA Switch to 
alternate IPA if 
in Auto Mode
YES
YES
IPA B Fault:  Power 
Supply, LDMOS, 
VSWR, Power 
Overload, Tempera-
ture, Input Power
The IPA can report 
upto 6 faults via 
their parallel con-
trol pins 
Any one fault active
IPA Switch to 
alternate IPA if 
in Auto Mode
YES
YES
PDU (Predriver) A 
Fault
The Predriver cur-
rent is monitored 
inside the PDU. A 
fault is sent if it is 
below the normal 
minimum current.
Predriver current is 
below TBD mA
IPA Switch to 
alternate IPA if 
in Auto Mode
NO
YES
PDU Predriver B 
Fault
The Predriver cur-
rent is monitored 
inside the PDU. A 
fault is sent if it is 
below the normal 
minimum current.
Predriver current is 
below TBD mA
IPA Switch to 
alternate IPA if 
in Auto Mode
NO
YES
Exciter A Power 
Output
Exciter A power 
level low
Trip point is 50% of 
nominal. Trip point 
adjustable by epot 
Exciter Switch 
to alternate 
Exciter if in 
Auto Mode
NO
YES