GatesAir Inc. ULXATSC Manual De Usuario

Descargar
Página de 86
2-24
888-2715-001
2/19/10
 
WARNING: Disconnect primary power prior to servicing.
Section 2 Operation
Maxiva ULX ATSC Series
User Manual
Figure 2-19  System Admin Screen
2.9.3.2
System Setup
Sys Pwr Out (W): Set this value to the system nominal power output. This value 
determines the 100% level on the GUI power out bar.
Center Freq (MHz): Enter the center frequency for the desired operational channel. 
This only sets the transmitter frequency. It doesn’t set the exciter frequency.
 Modulation Type: Select the system modulation type from the values displayed in 
the box.
AC Line Volt (VAC): Set this to the nominal AC line voltage at the transmitter site.
Number of Exciters: Set this to either 1 or 2 depending on how many exciters are in 
the transmitter.
Number of Cabinets: Set this to the number of PA cabinets in the system.
System Setup Entry: Enter a number from 1 to 8 in this field. For example if you 
want to set up the transmitter for CH29 and store it in entry 3, you enter 3 in the Sys-
tem Setup Entry. This will recall the data for entry 3. If no data is there, defaults will 
be loaded. Once all the calibrations for channel 29 are done you press SAVE SETUP. 
This will save the data to entry 3.