WARNING: Disconnect primary power prior to servicing.
Section 2 Operation
Maxiva ULX ATSC Series
User Manual
Figure 2-20  System Setup Screen
NOTE:
The Save Setup button allows storage of up to eight setups for the purpose of 
N+1 operation. All the calibrations for the transmitter are saved in the MCM 
module. This means the transmitter can change to anyone of 8 channels and be 
fully calibrated by simply recalling the set up entry. The N+1 controller will send 
the set up the entry that needs to be recalled, as well as set the exciter frequency.
2.9.3.3
Cabinet Setup
Cab Pwr Out (W): Set cabinet output power here. This is the power out of the cabi-
net before the combiner or filter. This needs to be set for each cabinet. Sets cabinet 
nominal power used to set ALC level.  Maximum cabinet power is limited to 10% 
over this value.
Number of PA’s: Enter the number of PA modules in the selected cabinet. This needs 
to be set for each cabinet.
 Number of IPA’s: Enter the number of IPA modules in the selected cabinet. This 
needs to be set for each cabinet.
Cooling Pumps: Set this to either 1 or 2 depending on how many pumps are in pump 
module/heat exchanger for this cabinet. This needs to be set for each cabinet.