3-4
888-2715-001
2/19/10
 
WARNING: Disconnect primary power prior to servicing.
Section 3 Diagnostics
Maxiva ULX ATSC Series
User Manual
The module three strike policy is:
• 
The TCU will try to restart the module three times within a 10 second 
window. After that, if a fault is still present, the module will be turned OFF 
until it receives the restart command from the Main Controller (ON 
Command).
• 
 There is a 3 second delay between restart attempts.
• 
The fault-strike restart process is the same as the system restart command, all 
of the module faults will be reset.
• 
 During the 10 second three-strike window, any of the nuisance faults will be 
reported to the Main Controller.
These are the module faults which will be allowed three strikes:
• 
Over Voltage Pallet
• 
 Under Voltage Pallet
• 
Over Temperature Module Controller
• 
Over Current Module Driver
• 
Over Temperature Pre-driver Heatsink
• 
Over Drive Module RF Input
• 
Over Drive Module RF Output
• 
Under Current Phase and Gain Board
• 
Over Current Phase and Gain Board
• 
Over Current Pallet
• 
Under Current Pre-Driver
• 
Over Current Pre-Driver
• 
Over Temperature Power Supply Board
• 
Low Voltage Output DC Converter
• 
Short Circuit 
• 
High Module Reflected Power