GatesAir Inc. ULXATSC Manual De Usuario
3-4
888-2715-001
2/19/10
WARNING: Disconnect primary power prior to servicing.
Section 3 Diagnostics
Maxiva ULX ATSC Series
User Manual
The module three strike policy is:
•
The TCU will try to restart the module three times within a 10 second
window. After that, if a fault is still present, the module will be turned OFF
until it receives the restart command from the Main Controller (ON
Command).
until it receives the restart command from the Main Controller (ON
Command).
•
There is a 3 second delay between restart attempts.
•
The fault-strike restart process is the same as the system restart command, all
of the module faults will be reset.
•
During the 10 second three-strike window, any of the nuisance faults will be
reported to the Main Controller.
These are the module faults which will be allowed three strikes:
•
Over Voltage Pallet
•
Under Voltage Pallet
•
Over Temperature Module Controller
•
Over Current Module Driver
•
Over Temperature Pre-driver Heatsink
•
Over Drive Module RF Input
•
Over Drive Module RF Output
•
Under Current Phase and Gain Board
•
Over Current Phase and Gain Board
•
Over Current Pallet
•
Under Current Pre-Driver
•
Over Current Pre-Driver
•
Over Temperature Power Supply Board
•
Low Voltage Output DC Converter
•
Short Circuit
•
High Module Reflected Power