GatesAir Inc. CZF Manual De Usuario

Descargar
Página de 148
 
  
APEX
 Exciter Incorporating FLO
 Technology
Navigating the LCD Display Screens
Details of the Exciter Status Screens
Page: 3-20
888-2604-001
03/08/07
WARNING: Disconnect primary power prior to servicing.
3.4.5.2
PLL Board Status Screen
PLLStatus.bmp
Figure 3-18  PLL Board Status Screen
The PLL Board screen is shown in Figure 3-18, with screen entries listed below.
• 15 Vdc: Input power from UDC interface board via connector J1.
• -15 Vdc: Input power from UDC interface board via connector J1.
• 8 Vdc: Input power from UDC interface board via connector J1.
• IF PLL Lock: 
(YES or NO) This PLL should normally be locked.
• RF PLL Lock:
(YES or NO) This PLL should normally be locked.
• 10MHz PLL Lock:  (N/A) The PLL board 10 MHz oscillator frequency is now refer-
enced to the external 1PPS GPS signal via the FPGA board and the PLL board DAC.
• 10 kHz. Reference: (N/A) This input is no longer used to lock the PLL board 10 MHz 
oscillator.
• Board Rev: This is the board revision for the PLL board.