Digital Monitoring Products Inc PC0179 Manual De Usuario

Descargar
Página de 38
Digital Monitoring Products 
iComSL
 
Series Universal Communicator Installation and Programming Guide
6
Remote Arming/Disarming
4.1 
DMP Virtual Keypad App / Virtual Keypad Browser
Using a Smartphone with the DMP Virtual Keypad App or using a computer with the Virtual Keypad Browser  
(www.myvirtualkeypad.com), you can connect to the iComSL Series Communicator to arm Areas, turn Outputs
on and off, and add, edit or remove Users. When using the iComSLCZ, you can control Z-Wave devices, Favorites
and Rooms.
Use 18-22 AWG for 
Power Supply connection
O1
O2
12 Vdc Aux. Output
+
-
 Control Panel 
B
AT
MODEL iComSL
PROG
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
GND
Zone 1
Zone 2
Control Panel EOL resistor
Figure 11: Virtual Keypad Application can be used to access the iComSL Series Communicator.
Figure 12: Burglary control panel zones connected to the iComSL outputs 
to arm and disarm the burglary control panel. 
A burglary control panel zone may be programmed as an arming zone and connected to a iComSL output (O1 or
O2) (See Figure 12). Program the output number in Armed Output or Remote Arming Output in Output Options
of the iComSL (See 12.4 Armed Output or 12.5 Remote Arming Output). The IComSL Communicator output
connections can be used with any of the applications listed in Applications Section.
remote armIng/dIsarmIng