Digital Monitoring Products Inc PC0179 Manual De Usuario

Descargar
Página de 38
iComSL
 
Series Universal Communicator Installation and Programming Guide 
Digital Monitoring Products
25
z-wave setup
17.10  EDIT Devices in FAVORITES
1.  Access the User Menu.
2.  Press COMMAND until ZWAVE SETUP? displays.
3.  Press any Select key. The keypad displays ADD LIST REMOVE.
4.  Press COMMAND again to display FAV XFER OPT. Select FAV and FAVORITE NUMBER: - is displayed.
5.  Enter a Favorite number between 1 and 20 and press COMMAND.
6. 
 The  Favorite number and name displays. Press COMMAND and the Favorite Name and ADD EDIT REMOVE
displays.
7.   Select EDIT and the first Z-Wave device stored in the Favorite displays. Remaining devices can be viewed by 
pressing the COMMAND key.
Note:  Z-Wave devices are displayed by device type; Lights first, followed by Doors, and Thermostats last. By
pressing the COMMAND key you can scroll through the devices assigned to the selected Favorite.
8.  Press any Select key to display the device name and the setting for the device.
9.  To change the setting, See Device Settings in Favorites.
10.   Once the device settings have been entered, the Favorite name and the next Z-Wave device stored in the
selected Favorite displays.
17.11  REMOVE Devices from FAVORITES
1.  Access the User Menu.
2.  Press COMMAND until ZWAVE SETUP? displays.
3.  Press any Select key. The keypad displays ADD LIST REMOVE.
4.  Press COMMAND again to display FAV XFER OPT. Select FAV and FAVORITE NUMBER: - is displayed.
5.  Enter a Favorite number between 1 and 20, press COMMAND.
6. 
 The  Favorite number and name displays. Press COMMAND and the Favorite Name and ADD EDIT REMOVE
displays.
7.   Select REMOVE and the first Z-Wave device stored in the Favorite displays. Remaining devices can be viewed 
by pressing the COMMAND key.
8.   Press any Select key to remove the device from the Favorite. REMOVE DEVICE FROM FAV? NO YES displays.
When YES is selected, the device is removed from the Favorite.
17.12  Transfer Controller (XFER)
This option allows the transfer of all existing Z-Wave devices that are currently programmed in another
manufacturer’s Z-Wave portable controller to your system.
 This operation will overwrite all Z-Wave devices that are programmed in your system. This option typically
occurs at the time your DMP Z-Wave controller is installed.
Initiate the transfer at the other manufacturer’s Z-Wave portable controller after starting the transfer on
the DMP keypad. Z-Wave devices are NOT overwritten until the transfer has been initiated at the other
manufacturer’s Z-Wave portable controller. The transfer should not be stopped once the process has been
initiated from the other manufacturer’s Z-Wave portable controller.
Transfer Operation:
1.  Access the User Menu.
2.  Press COMMAND until ZWAVE SETUP? displays.
3.   Press any Select key. The keypad displays 
ADD LIST REMOVE.
4.   Press COMMAND again to display FAV XFER OPT. Select XFER. The keypad displays XFER WILL DELETE
EXISTING DEVICES then displays XFER CNTRL SURE? YES NO.
5.   Select YES to to allow receipt of Z-Wave devices to your system. The keypad displays TRANSFERRING Z-WAVE
DEVICES. Pressing the Back Arrow key cancels the transfer. Select NO to exit the XFER menu and return
to ZWAVE SETUP?. All programming will still be intact on the DMP Z-Wave controller and will cancel the
transfer.
6.   Initiate the transfer at the other manufacturer’s Z-Wave portable controller. All Z-Wave devices are added
to the system with a default name (device type and number). A 16-character name may be assigned to the
Z-Wave devices after the transfer is complete. When the transfer is complete the screen will display ZWAVE
SETUP?.
Note: If TRANSMISSION FAILED displays on the screen, your system memory is cleared of all prior Z-Wave devices
programming and will need to add each Z-Wave device individually.