Rothenbuhler Engineering Company Inc 1673-2 Manual De Usuario

Descargar
Página de 68
1673 OPERATION MANUAL REV A 
32 
 
Figure 4-3 Activating the Remote Unit 
4.1.5. 
Press the ON switch.  Observe the yellow ON light is on and not flashing.  Press the 
BATT TEST switch and verify the battery voltage. If the battery voltage is below 7.0 V, the unit 
must be recharged before use.  
4.1.6. 
If the green RX light is on, it suggests there may be an interfering radio signal or noise 
present.  The RX light is similar to breaking squelch on a handheld radio and does not necessarily 
indicate operation is degraded. 
4.1.7. 
Verify the green READY light is on, while the red ARMED light remains off. 
4.1.8. 
Install the tube into the Shock Tube Firing Tip, and install the tip into the jacks on the 
front panel of the Remote as described in section 2.11. 
4.1.9. 
Install the enable key into the Remote Unit, and observe the yellow KEY light blinks. 
4.1.10. 
Close the lid on the Remote Unit for environmental protection. 
4.1.11. 
Repeat Sections 4.1.3 to 4.1.9 for the remaining Remote Units to be used in the 
operation.