Lectrosonics Inc HHAB1 Manual De Usuario

Descargar
Página de 20
HHa
LECTROSONICS, INC.
12
IMPORTANT:  Be sure to set the attenuator control back 
to its original setting (“F”) for normal operation. or a 
subsequent user may think the unit is malfunctioning or 
has a poor signal to noise ratio.
LO/MID/HI (bass/mid/treble) - HHVMC only
The HHVMC head includes VariMic
TM
 equalization 
adjustments to boost or cut the frequency response in 
LOW, MID and HIGH ranges. The LOW and HIGH con-
trols will boost/cut by up to 8 dB while the MID control 
will boost/cut up to 6 dB.
LOW
MID
HIGH
The pointer is between the 
darkened dots.
The controls are set to “zero” 
(no boost  or cut) in this photo
These controls operate as standard tone controls in 
that a counterclockwise adjustment cuts the response 
in that band and a clockwise adjustment boosts the 
response.
+10
0dB
-10
10Hz
100Hz
1KHz
10KHz
+5
-5
VariMic Tone Control Range
Treble
Bass
Midrange
Boost
Cut
Treble
Midrange
Bass
Mic Capsule Adjustments
(EXPERT LEVEL ADJUSTMENT)
These adjustments significantly alter the gain and 
tonal quality of the microphone, and are to be used 
only in special circumstances.
Caution: Always make the final decision about 
sound quality with the windscreen in place.
Remove the windscreen using the supplied wrench.
Align flats on the wrench with flats on the capsule.
Attenuator Adjustment
The HHC & HHVMC heads include an attenuator in 
the preamp circuitry to provide an additional 15 dB of 
headroom when needed for extremely loud voices.
The attenuator should ONLY be used when the gain 
control is already turned all the way down
 and the 
audio is still driving the preamp into significant limiting 
where both -20 and -10 dB LEDs stay lit all or most of 
the time during peaks in the audio.
-40
-20
0
Gain
0
Gain set to 
minimum (0) on 
the LCD.
LEDs on control panel
The attenuator control is a 16 position switch that 
attenuates the audio in 1 dB steps. It is marked 0 
through F where F is minimum attenuation and 0 is 
maximum attenuation. Rotating it clockwise increases 
the loudness, and counter clockwise decreases the 
loudness.
Attenuator switch set at F for normal operation.
EQ controls
(HHVMC only)
Attenuator 
control
Resonance tuned 
suspension
HHVMC capsule