Checkpoint Systems Inc. EVOLVEF10 Manual De Usuario

Descargar
Página de 71
F10 Installation Manual 
                         Rev. *60          
 
20 of 71
 
Common Wider Floor Cuts 
It is possible to create a wider system by combing either of the smaller two floor kits (refer to 
Figures 3.1 and 3.2 above). For example, to cover a 3m mall opening, a 1m and 2m kit are ordered. 
Figure 3.6 below shows exact dimensions of the trough (floor cuts) when the F10, 1 meter and 2 
meter systems are combined. Figure 3.7 shows two (2) F10, 2 meter systems installed side-by-side.  
 
354.5cm [139.6in]
Matching Board
Locations 
117.5cm 
[46.27in]
224.2cm [88.3in]
35.5cm
[14in]
21.8cm 
[8.6in]
 
        Figure 3.6 2m and 1m System for 3m Opening 
 
  Note: Figures are Not Drawn to Scale 
 
461cm [181.5in]
Matching Board 
Locations
35.5cm
[14in]
117.5cm 
[46.27in]
117.5cm 
[46.27in]
    
             Figure 3.7 Side-by-Side 2m Systems for 4m Opening 
 
   Note:
 
The Impedance Matching Board placement for the F10, 2 meter system is between the assemblies. 
For the F10, 1 meter system, board placement is beside the antenna assembly. The ENT Tubing 
(with coax cable) can be routed in any direction from antenna to electronics. A minimum spacing of 2” 