Wood Surface Installation 
For mounting to wood, use a #7 x ½” (0.38cm x 1.3cm) hex head screw (CKP P/N 7939172).  
 
Figure 3.8  Wood Surface Installation
  
 
Drywall Surface Installation 
For mounting to drywall, use a #8 x 1” (0.42cm x 2.5cm) panhead screw (CKP P/N 7308823), 
which is a Power Fastener Zip-it (P/N 02348).  
 
Figure 3.9  Drywall Installation 
1. 
Using the proper diameter bit, drill a hole into 
the base material to a depth of at least 0.6cm 
[1/4”] deeper than the embedment required. 
Blow the hole clean of dust and other material. 
 
2. 
Select the installation tool and drive socket to 
be used. Insert the head of the screw into the 
hex head socket driver.  
 
 
 
 
3. 
Place the point of the screw through the fixture 
into the pre-drilled hole and drive the anchor in 
one steady continuous motion until it is fully 
seated at the proper embedment.  
1. 
Insert either # 2 or # 3 Phillips driver bit into 
the recess of the ZiP-It anchor head. Use a 
manual screwdriver or a low-rpm 
battery-powered electric screw gun. 
 
2. 
Push the ZiP-It anchor into the surface of the 
wallboard until the two cutting blades 
penetrate the surface. Using gentle forward 
pressure, rotate the ZiP-It until the collar sets 
flush to the surface of the wall. 
 
3. 
Put the fixture in place, insert screw and 
tighten until it feels secure. As the screw is 
threaded into the nylon versions, the point will 
expand resulting in increased load capacity in 
thicker wallboard.  
Note: When using an electric screw gun for 
application, set clutch and use a slow speed  
(do not exceed approximately 300-400 RPM).