Install the Gate Base
The floor mounting of the slave gate is used to mark the holes for drilling.
Determining the Mounting Holes
1
Use the floor mounting plate from the disassembled gate to mark the holes for all of the 
gates.
2
Ensure that the orientation of the gates is consistent, so that each gate faces the same 
way. Notice in the diagram below that each same mounting plate faces in the same 
direction.
3
When the position of the antennas has been marked (in conjunction with the Site 
Survey document), the floor plate, which is the hole template, is to be used to drill the 
mounting holes and the holes for the cable entry. The dimensions are shown below:
Figure 1.8 
Floor Plate Dimensions
Screw Anchor Type
The size and type of the screw anchors depends considerably on the strength of the base or 
floor. The anchors should be capable of withstanding a permissible load of at least 5 kN 
per anchor for all load directions (e.g. for concrete floor Hilti HVA anchors with HAS-(E) 
M8 (5/16”) threaded rods or Hilti HIS-N M8 (5/16”) threaded inserts). The size of the 
mounting holes in the antenna is 10 mm (.39”). The length of the anchors or bolts should 
Adjusting screw
Cable opening - floor
Mounting holes
max. M10 (3/8”)
541 mm (21.3”)
501 mm (19.7”)
421 mm (16.6”)
87 mm (3.4”)
759 mm (29.8”)
10 mm (0.4”)
Mounting plates oriented 
in same direction