Checkpoint Systems Inc. FX2012 Manual De Usuario
NGL FX Installation Manual
Rev. *
49 of 84
Figure 28 Single Aisle System
Figure 29 Multi-Aisle System
12. Move to the PAB of the PAB/SAB combination that you want to designate as master.
Attach a serial cable to the TR4215 board and using the DMS tool, connect to the board.
13. Navigate to the DMS Switch Settings window and click on the Band tab.
14. Select "Master" from the Master/Submaster selection box.
15. Click Apply. A success setting message box will come up. Click OK. Then, click
Disconnect to close down the DMS. Disconnect the serial cable from the TR4215 board.
16. Move to the PAB of a PAB/SAB combination that will be designated as SubMaster.
Attach a serial cable to the TR4215 board and using the DMS tool, connect to the board.
17. Navigate to the DMS Switch Settings window and click on the Band tab.
18. Select "Submaster" from the Master/Submaster selection box.