General Installation Instructions
Please consider besides these general instructions also any product-specific 
instructions in the “Installation” chapter of this manual. 
B1
Unpacking
Check the equipment for any transport damage. If the unit is mechanically 
damaged, if liquids have been spilled or if objects have fallen into the unit, 
it must not be connected to the AC power outlet, or it must be immediately 
disconnected by unplugging the power cable. Repair must only be performed 
by trained personnel in accordance with the applicable regulations.
B2
Installation Site
Install the unit in a place where the following conditions are met:
                  
within the specified limits during operation of the unit. Relevant values 
are the ones at the air inlets of the unit (refer to Appendix 1)
 ! #$
%# #'*+
precautions must be taken before and after operation (refer to Appendix 
1)
 3 #
unit are a functional part of the design and must not be blocked in any 
way during operation (e.g. by objects placed upon them, placement of the 
unit on a soft surface, or installation of the unit within a rack or piece of 
furniture)
  7 %-
light, spotlights)
B3
Earthing and Power Supply
Earthing of units with mains supply (class I equipment) is performed via
%;<+ #3
battery operation (< 60 V, class III equipment) must be earthed separately. 
Earthing the unit is one of the measures for protection against electrical shock 
hazard (dangerous body currents). Hazardous voltage may not only be caused
by a defective power supply insulation, but may also be introduced by the 
connected audio or control cables.
If the unit is installed with one or several external connections, its earthing 
must be provided during operation as well as while the unit is not operated. 
If the earthing connection can be interrupted, for example, by unplugging 
the mains plug of an external power supply unit, an additional, permanent 
earthing connection must be installed using the provided earth terminal. 
Avoid ground loops (hum loops) by keeping the loop surface as small as 
possible (by consequently guiding the earth conductors in a narrow, parallel 
way), and reduce the noise current flowing through the loop by inserting an 
additional impedance (common-mode choke). 
Installation