ALIGNMENT AND TEST PROCEDURES
7-16
August 2000
Part No. 001-2001-200
7.4.8  REPEATER OPERATION
New HSDB Test
1. On the MPC, switch settings for RS-485 operation 
are shown in Figure 7-10.
Figure 7-10   NEW HSDB SWITCH SETTINGS
2. Verify that the repeater is programmed for "Stand 
Alone" mode in Setup Parameters-F4 (see Section 
4.3.1).
3. The repeater is now in Normal Operation mode.  
Verify by the MPC front panel indicators that no 
HSDB alarms have occurred (Alarm Number 10) 
see Table 1-2.
Handshake Test
1. Program an LTR portable or mobile for the follow-
ing parameters.
Home Repeater - Same as repeater number.
Area - Same as repeater’s area bit.
Home Repeater’s Channel Number - 
Sameas repeater’s channel number.
Group 1 Encode/Decode - 1
2. The repeater is now in Normal Operation mode.
3. Key the radio several times on the programmed 
System/Group.  Access should occur every time.  
(Proper Tx/Rx antenna connections are assumed.)
Alarm Test
1. The repeater is now in Normal Operation mode.
2. Verify by the MPC front panel indicators that no 
alarms have occurred (see Table 1-2).
Figure 7-11   J2 TERMINAL BLOCK
ON
ON
S3
S2
2
1
8
7
6
5
4
3
2
1
4
3
2
1
33
34
J2
TXS+
TXS-
RXS-
RXS+
RXA+
RXA-
TXA+
TXA-