NOTE: Although the wireless transmission range is up to 100 feet, 
it is greatest with no obstructions between the Monitor (transmitter) 
and Receiver.  Any obstructions, such as walls, floors, and ceilings 
will reduce the range of transmission, and relocation of the 
Receiver may be required. Retest with each location to ensure 
proper operation   
6.  Mount the Receiver vertically by using the screws or adhesive strip 
supplied. 
7.  Install the front cover by placing the bottom flanges into the housing 
and rotating the cover upward until the top latches into the housing. 
 
 
O
peration 
 
System Monitoring 
The STATUS LED will blink green approximately once per minute (called a 
heartbeat) to indicate that the unit is functioning properly. Usually the 
FILTERSCAN
®
 will be in the standby mode, conserving power. It wakes 
up periodically to monitor air filter condition, battery level, and system 
operation.  If no alarm conditions are detected, the 
FILTERSCAN
®
 goes 
back to sleep after several minutes of monitoring.   
 
 
NOTE: Should there be a power failure the 
FILTERSCAN
®
 will save all 
parameters such as the clean air filter calibration and the current state of 
the air filter.  When power is restored, the 
FILTERSCAN
®
 Monitor will 
continue operation with no user action required.  The same applies when 
replacing depleted batteries. 
 
Alarm Modes 
The 
FILTERSCAN
®
 provides both audible and or visual alarms indicating 
a clogged air filter, a low battery, or a system malfunction.  There is also a 
wireless option which allows remote monitoring of system conditions. 
 
 
NOTE: The HVAC system blower fan must be running when the
 
FILTERSCAN
®
 Monitor attempts to check air filter condition. Since the 
FILTERSCAN
®
 Monitor checks the air filter condition periodically, it may 
take several days to detect, trigger, and alarm a clogged filter condition. 
 
 
Clogged Air Filter
  
When the 
FILTERSCAN
®
 detects a clogged air filter, an alarm condition 
is triggered.  The red STATUS LED will illuminate, blinking five times 
approximately every ten minutes until the alarm condition is reset.  There 
will also be an audio alert which corresponds to the visual alarm indication.  
The clogged filter alarm is reset by installing a new, clean air filter, 
depressing the CALIBRATE button, and then following the instructions in 
the section "Calibrating When Installing a New Air Filter".  
NOTE: A new air filter should always be installed whenever the 
CALIBRATE operation is performed.  
 
 
Low Battery 
 
When the 
FILTERSCAN
®
 detects a low battery condition, an Alarm 
condition is triggered.  The STATUS LED will blink yellow approximately 
once per minute to indicate a low battery in the Monitor. Replacing the 
Monitor batteries (see the Appendix for instructions) will reset the alarm 
condition.  
 
 
Malfunction 
 
When the 
FILTERSCAN
®
 detects an internal malfunction, an alarm 
condition is triggered. The red STATUS LED will illuminate continuously 
until the malfunction is corrected. In the unlikely event this should occur, 
remove power from the 
FILTERSCAN
®
 by removing the batteries, 
Formatted: Indent: Left:  1.97", Numbered +
Level: 1 + Numbering Style: 1, 2, 3, … + Start
at: 1 + Alignment: Left + Aligned at:  0.03" +
Tab after:  0.28" + Indent at:  0.28", Tab stops:
Not at  0.28"