CleanAlert LLC FS-242 Manual De Usuario
7
NOTE: Although the wireless transmission range is up to 100 feet,
it is greatest with no obstructions between the Monitor (transmitter)
and Receiver. Any obstructions, such as walls, floors, and ceilings
will reduce the range of transmission, and relocation of the
Receiver may be required. Retest with each location to ensure
proper operation
it is greatest with no obstructions between the Monitor (transmitter)
and Receiver. Any obstructions, such as walls, floors, and ceilings
will reduce the range of transmission, and relocation of the
Receiver may be required. Retest with each location to ensure
proper operation
6. Mount the Receiver vertically by using the screws or adhesive strip
supplied.
7. Install the front cover by placing the bottom flanges into the housing
and rotating the cover upward until the top latches into the housing.
O
peration
System Monitoring
The STATUS LED will blink green approximately once per minute (called a
heartbeat) to indicate that the unit is functioning properly. Usually the
heartbeat) to indicate that the unit is functioning properly. Usually the
FILTERSCAN
®
will be in the standby mode, conserving power. It wakes
up periodically to monitor air filter condition, battery level, and system
operation. If no alarm conditions are detected, the
operation. If no alarm conditions are detected, the
FILTERSCAN
®
goes
back to sleep after several minutes of monitoring.
NOTE: Should there be a power failure the
FILTERSCAN
®
will save all
parameters such as the clean air filter calibration and the current state of
the air filter. When power is restored, the
the air filter. When power is restored, the
FILTERSCAN
®
Monitor will
continue operation with no user action required. The same applies when
replacing depleted batteries.
replacing depleted batteries.
Alarm Modes
The
FILTERSCAN
®
provides both audible and or visual alarms indicating
a clogged air filter, a low battery, or a system malfunction. There is also a
wireless option which allows remote monitoring of system conditions.
wireless option which allows remote monitoring of system conditions.
NOTE: The HVAC system blower fan must be running when the
FILTERSCAN
®
Monitor attempts to check air filter condition. Since the
FILTERSCAN
®
Monitor checks the air filter condition periodically, it may
take several days to detect, trigger, and alarm a clogged filter condition.
Clogged Air Filter
When the
FILTERSCAN
®
detects a clogged air filter, an alarm condition
is triggered. The red STATUS LED will illuminate, blinking five times
approximately every ten minutes until the alarm condition is reset. There
will also be an audio alert which corresponds to the visual alarm indication.
The clogged filter alarm is reset by installing a new, clean air filter,
depressing the CALIBRATE button, and then following the instructions in
the section "Calibrating When Installing a New Air Filter".
approximately every ten minutes until the alarm condition is reset. There
will also be an audio alert which corresponds to the visual alarm indication.
The clogged filter alarm is reset by installing a new, clean air filter,
depressing the CALIBRATE button, and then following the instructions in
the section "Calibrating When Installing a New Air Filter".
NOTE: A new air filter should always be installed whenever the
CALIBRATE operation is performed.
CALIBRATE operation is performed.
Low Battery
When the
FILTERSCAN
®
detects a low battery condition, an Alarm
condition is triggered. The STATUS LED will blink yellow approximately
once per minute to indicate a low battery in the Monitor. Replacing the
Monitor batteries (see the Appendix for instructions) will reset the alarm
condition.
once per minute to indicate a low battery in the Monitor. Replacing the
Monitor batteries (see the Appendix for instructions) will reset the alarm
condition.
Malfunction
When the
FILTERSCAN
®
detects an internal malfunction, an alarm
condition is triggered. The red STATUS LED will illuminate continuously
until the malfunction is corrected. In the unlikely event this should occur,
remove power from the
until the malfunction is corrected. In the unlikely event this should occur,
remove power from the
FILTERSCAN
®
by removing the batteries,
Formatted: Indent: Left: 1.97", Numbered +
Level: 1 + Numbering Style: 1, 2, 3, … + Start
at: 1 + Alignment: Left + Aligned at: 0.03" +
Tab after: 0.28" + Indent at: 0.28", Tab stops:
Not at 0.28"