55
—  Network Protocal:TCP/Client, Port ID: 8899; Application IP address:10.10.100.100; 
„  Module 2#  Setting: 
—  Works as STA mode;                                           
—  WAN connection type: Static IP: 10.10.100.101;                                                               
—  Network Protocal:TCP/Client, Port ID: 8899; Application IP address:10.10.100.100; 
—  LAN IP address: 10.10.99.254 (Different net segment with WAN port); 
„  Module 3#  Setting: 
—  Works as STA mode;                                           
—  WAN connection type: Static IP: 10.10.100.102;                                                               
—  Network Protocal:TCP/Client, Port ID: 8899; Application IP address:10.10.100.100; 
—  LAN IP address: 10.10.98.254 (Different net segment with WAN port); 
       
 
Figure 50.  Wireless Data Acquisition Card Setting