Programming
Option 45: Sensor Alarm Restoral Report
(Default = off)
Determines whether the panel reports sensor alarm restorals 
(on), or not (off). The following table describes the possible 
settings.
To turn on Sensor Alarm Restoral Report, press:
Add—Option #—45—1, 2, or 3—DONE.
To turn off Sensor Alarm Restoral Report, press:
Delete—Option #—45—DONE.
Option 46: Fire Shutdown - AVM (Default = off)
Determines whether system sirens are silenced during a 2-way 
audio session (on) or not (off). Beeps sound every 10 seconds 
while sirens are silenced.
To turn on Fire Shutdown - AVM, press:
Add—Option #—46—DONE.
To turn off Fire Shutdown - AVM, press:
Delete—Option #—46—DONE.
Option 47: AVM Mode (Default = off)
Determines whether the panel hangs up and waits for a call-
back from the central station operator before starting an audio 
session (on), or stays on line with the central station for an 
instant audio session (off).
Note 
Option 33: Audio Verification must be on for this feature 
to work.
To set AVM Mode to Callback, press:
Add—Option #—47—DONE.
To set AVM Mode to Instant, press:
Delete—Option #—47—DONE.
Option 48: Panic Talk - AVM (Default = off)
Determines whether the central station operator can talk to the 
user during a silent alarm (on) or just listen in on the premises 
(off).
Silent alarms occur when sensors learned into groups 02 or 03 
are tripped, when the Panic Code is entered, or when the panel 
Police button is pressed and Option 74: Silent Panel Police 
Panic is turned on.
Note 
Option 33: Audio Verification must be on for this feature 
to work.
To turn on Panic Talk - AVM, press:
Add—Option #—48—DONE.
To turn off Panic Talk - AVM, press:
Delete—Option #—48—DONE.
Option 49: Arming LEDs Shutdown (Default = off)
Determines whether the panel LEDs (buttons) turn off 30 sec-
onds after the last button press (on), or remain on for the entire 
arming period (off).
To turn on Arming LEDs Shutdown, press:
Add—Option #—49—DONE.
To turn off Arming LEDs Shutdown, press:
Delete—Option #—49—DONE.
Option 50: RF Jam Detect (Default = off)
Determines whether the panel checks for and reports RF inter-
ference/jam to the central station (on), or not (off).
If this option is on and the panel receives a constant 319.5 
MHz signal, the panel speaker announces “Option 50 detected” 
and reports the condition to the central station. If this option is 
off, the panel does not detect an RF jam.
Note 
For UL listed systems, RF Jam Detect must be on.
To turn on Arming LEDs Shutdown, press:
Add—Option #—50—DONE.
To turn off Arming LEDs Shutdown, press:
Delete—Option #—50—DONE.
Option 51: 24 Hour Sensor Tamper (Default = off)
Determines whether the system (armed or disarmed) goes into 
and reports an alarm anytime a sensor tamper switch is tripped 
(on), or only when the system is armed and a tamper switch of 
an armed sensor is tripped (off).
Sensor Alarm Restoral Settings
Setting
When Restorals are Reported
Off
No restoral reporting
1
Immediately after sensor is closed or restored
2
After siren timeout expires
3
When system is disarmed