Programming
Option 40: Trouble Beeps (Default = on)
Determines whether the panel, X-10, and hardwire interior 
sirens sound six beeps every minute when a trouble condition 
occurs (on) or not (off). The following conditions cause trouble 
beeps:
AC power failure
Low CPU battery
Sensor failure (supervisory)
Sensor trouble (low battery or tripped tamper)
Fail to communicate
No Activity timer has timed out. Trouble beeps continue 
for 5 minutes and if the panel does not see activity, trouble 
beeps stop and the panel reports the no activity to the cen-
tral station.
Trouble beeps can be silenced by arming or disarming the sys-
tem, or by pressing the STATUS button. Trouble beeps resume 
4 hours later if the trouble condition is not cleared.
Note 
For UL listed systems, Trouble Beeps must be on.
To turn on Trouble Beeps, press:
Add—Option #—40—DONE.
To turn off Trouble Beeps, press:
Delete—Option #—40—DONE.
Option 41: Chime Voice (Default = off)
Determines whether the panel announces the sensor number 
and name (on) or only sounds beeps (off), when the CHIME 
Doors or CHIME Special Motion features are on and sensors in 
groups 10, 13, and 25 are tripped while the system is disarmed.
To turn on Chime Voice, press:
Add—Option #—41—DONE.
To turn off Chime Voice, press:
Delete—Option #—41—DONE.
Option 42: Speaker Level (Default = 8)
Sets the volume of voice messages from the panel speaker.
The volume can be set from 1 (lowest) to 8 (highest). Turning 
off this option returns the setting to the default value.
To set Speaker Level, press:
Add—Option #—42—1 - 8—DONE.
To turn off Speaker Level (return to default), press:
Delete—Option #—42—DONE.
Option 43: Numeric Pager/Voice Event Notification 
Phone Number (Default = off)
Lets you program up to a 26-digit phone number for numeric 
pager or voice event notification (on), or delete an existing 
phone number (off).
When used to call a numeric pager, a 3-digit code appears on 
the pager display to identify the report. When used to call a 
remote phone, a person at the remote phone location can hear 
system voice alarm announcements. See the “Testing” section 
for more information.
Press Test for each required pause, Add for a *, and Delete for 
a # (each of which uses one of the 26 available places).
Note 
Some pagers may require 3 or 4 additional pauses after 
the last digit to work correctly.
To set Numeric Pager/Voice Event Notification Phone 
Number, press:
Add—Option #—43—Up to 26 digits—DONE.
Note 
Pressing DONE is required if you enter fewer than 26 
digits. The phone number is automatically stored without 
pressing DONE if all 26 places are used.
To delete Numeric Pager/Voice Event Notification Phone 
Number, press:
Delete—Option #—43—DONE.
Option 44: Numeric Pager/Voice Event Notification 
Phone Mod 3 (Default = 09)
Determines the report content and reporting format when 
Option 43: Numeric Pager/Voice Event Notification Phone 
Number is programmed. The following table describes the 
choices. All entries must be 2 digits.
To set Numeric Pager/Voice Event Notification Phone 
Mod 3, press:
Add—Option #—44—08, 09, or 10—DONE.
To reset Numeric Pager/Voice Event Notification Phone 
Mod 3 (return to default), press:
Delete—Option #—44—DONE.
Phone Mod 3
Setting #
Content
Format
08
Latchkey, No Activity, Phone Test, 
Openings, Closings, Fail to Open/
Close, AC Power Restorals/
Failures
Numeric 
Pager
09
Same as setting 8 plus Alarms
Numeric 
Pager
10
Alarms only
Voice Event 
Notification