Testing the System
Off-Site Phone Operation
Test the system from a remote phone using the commands in 
the following table.
Central Station Communication
After performing sensor and phone tests, check that the system 
is reporting alarms successfully to the central station.
To test communication with the central station:
1.
Call the central station and tell the operator that you 
will be testing the system.
2.
Arm the system.
3.
Test each of the wireless panic buttons and trip at least 
one sensor of each type (fire, intrusion, etc.) to verify 
that the appropriate alarms are working correctly. 
4.
When you finish testing the system, call the central sta-
tion to verify that the alarms were received.
Pager Communication
Use the following table to determine what the numeric mes-
sage is reporting.
2-Way Voice Operation
To initiate an audio session, the central station operator must 
perform the following steps:
1.
After the panel has completed reporting the alarm, pick 
up the CS phone and press the 
‚ button to start the 
audio session.
2.
Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 
to listen.
3.
Press 99 to terminate the session.
Note 
Panel voice announcements are silenced during AVM 
sessions. If the operator does not terminate the session 
correctly, panel announcements may not occur for up to 
90 seconds after the operator hangs up.
Note 
To conduct an audio session using remote phone access 
see the Table “Phone Commands for Remote Access” in 
the “Testing” section.
Remote Phone Operation
System Function
Phone Command
DISARM
* + CODE + 1
ARM Doors/Windows
* + CODE + 2
ARM Motion Sensors
* + CODE + 3
ARM Doors/Windows 
with No Entry Delay
* + CODE + 2 + 2
ARM Motion Sensors 
with Latchkey
* + CODE + 3 + 3
ARM Doors/Windows 
and Motion Sensors
* + CODE + 2 + 3
ARM Doors/Windows 
with No Entry Delay 
and Motion Sensors 
with Latchkey
* + CODE + 2 + 2 + 3 + 3
Toggle Lights
* + CODE + 0
System Status
* + CODE + # + 1
Audio Verification
* + CODE + 5 + X (X = a 
command from Audio 
Verification Set)
Terminate Session
* + CODE + 9
User Codes for Opening and Closing Reports
Arm or Disarm from:
Reports as User:
Panel or Remote Handheld 
Touchpad
0
Keychain Touchpad
1-24 (sensor number)
Master Code
30
Access Codes 1-5
31-35
Panic Code
36
Pager Reporting Message
Reports
Numeric 
Message
Phone Test
-101 -101
AC Power Restoral
-102 -102
AC Power Failure
-103 -103
Latchkey
-104 -104
No Activity
-105 -105
Panic Code
-106 -106
Emergency
-107 -107
Intrusion
-108 -108
Fire
-109 -109
Openings
-110 -110
Closings
-111 -111
Fail to Open
-112 -112
Fail to Close
-113 -113