Simon XT
Installation Manual
24
Connecting hardwired devices
The panel has seven screw terminals and two telephone connections (Figure 5). The screw terminals connect 
AC power, sirens, and/or hardwired detectors. 
Program sensors and devices before you install them. Follow the instructions in   to add the sensors to panel 
memory.  
Figure 5. Simon XT terminal connections
HW1 I/O, HW2 in, and HW1&2 DC out terminals
The HW1 I/O terminal is dual purpose and can be used for either siren or hardwired contact connections. The 
HW2 in terminal is an input only. 
Interior sirens
From the factory, the HW1 I/O input is set up for interior siren operation (status and alarm sounds). HW1&2 
DC out
 provides the positive (+) voltage.
Note:  The total current available from the HW1&2 DC out terminal is 250 mA at up to 120°F (49°C). A 24-hour battery standby for 
UL Requirements will be met with a maximum load of 250 mA.
With Hardwired Siren Supervision turned on, sirens connected to HW1 I/O are supervised and require a 
4.7 kohm resistor in the circuit. If this terminal is not used, turn Hardwired Siren Supervision off. 
9 VAC in
Battery – neg
Battery compartment
Battery + pos
HW1&2 DC out
HW2 in
HW1  I/O
RJ11 connector (PHONE)
RJ45 connector (LINE) 
Tamper switch