UTC Fire & Security Americas Corporation Inc 910C-SIMON Manual De Usuario
Simon XT
Installation Manual
44
Ring hang ring
a
1
Determines when the panel answers a remote phone access or Enterprise call.
Depending on whether an answering machine exists at the panel location, offsite
access to the panel can be done with a series of phone calls or just one. For offsite
access where an answering machine does not exist, the user or Enterprise operator
simply calls the panel location once and listens for 10 rings. The panel should answer
after the tenth ring.
Depending on whether an answering machine exists at the panel location, offsite
access to the panel can be done with a series of phone calls or just one. For offsite
access where an answering machine does not exist, the user or Enterprise operator
simply calls the panel location once and listens for 10 rings. The panel should answer
after the tenth ring.
For offsite access where an answering machine exists, the user or Enterprise operator
must perform the following steps:
must perform the following steps:
• Call the panel location.
• Let the phone ring once, then hang up.
• Wait at least 10 seconds but not more than 40, then call the panel location again.
• Let the phone ring once, then hang up.
• Wait at least 10 seconds but not more than 40, then call the panel location again.
The panel should answer on the first ring.
Ring/hang/ring setting number and sequence of rings after which the panel answers:
1
Ring/hang/ring or ten rings
2
Ring/hang/ring/hang/ring or ten rings
3
Ring/hang/ring/hang/ring/hang/ring or ten rings
4
Ten rings
5
Ring/hang/ring
6
Ring/hang/ring/hang/ring
7
Ring/hang/ring/hang/ring/hang/ring
Off Disabled—no remote (offsite) access
Dial delay
30 seconds
Determines whether the panel delays dialing programmed phone numbers before
sending reports (on).
If Opening (Disarming) Reports is on, the panel
does not delay dialing if the system is disarmed before the delay time expires. The panel
dials immediately for both the alarm and opening report.
sending reports (on).
If Opening (Disarming) Reports is on, the panel
does not delay dialing if the system is disarmed before the delay time expires. The panel
dials immediately for both the alarm and opening report.
Note: Regardless of this option setting, the panel always dials immediately for fire
alarms, AC power failure and low battery reports.
The combined dialer delay and entry delay cannot exceed 60 seconds for a UL Listed
installation.
installation.
Call wait code
Off
The call waiting code is dialed by the panel before a phone number to disable call
waiting. Verify that the end-user has call waiting with his phone service provider before
changing this option from its default.
waiting. Verify that the end-user has call waiting with his phone service provider before
changing this option from its default.
CAUTION: Changing this option from its default without call waiting will prohibit
the panel from calling the central station.
The call waiting code is programmed the same way as a phone number.
a.
Not investigated for use by UL.
Table 15. Phone options (continued)
Function
Default
Description