48
Low CPU battery On
Determines whether the panel sends a low CPU battery report to the central station 
when the panel backup battery voltage drops
Sen alarm 
restore
Off
Determines whether the panel reports sensor alarm restorals (on) or not (off). Setting 
when restorals are reported: 
1.
Immediately after sensor is closed or restored after dial delay.
2.
After siren timeout expires if sensor is restored. 
3.
When system is disarmed if sensor is restored. 
24-hour sensor 
tamper
Off
Determines whether the system (armed or disarmed) goes into and reports an alarm 
anytime a sensor tamper switch is tripped (on), or only when the system is armed and a 
tamper switch of an armed sensor is tripped (off).
Supervisory 
tamper 
a
Off
Determines whether the panel sends supervisory reports to a central station as a 
tamper (on) or a supervisory (off). 
This option is typically used only in Europe where a supervisory condition is required to 
report as a tamper.
No usage 
Off
Determines whether the panel sends a No Usage report to the central station if the user 
has not operated the system before the programmed time expires (on) or not (off). The 
timer starts each time the system is disarmed. 
This is a customer service feature that alerts the central station if a customer is not 
using their security system. The service provider can then contact the customer to find 
out why the system is not being used, and help correct any problems for the customer.
Swinger 
shutdown
On
Determines whether the panel prevents the same sensor from activating an alarm more 
than once in a single arming period (on) or not (off). 
Note:  Swinger Shutdown does not affect smoke and fire sensors.
Program report
Off
Determines whether the panel sends a report to the central station anytime the 
programming mode is entered/exited (on) or not at all (off). The panel sends a report 
whenever the dealer (Utility 1) or installer (Utility 2) code is used to enter programming 
mode and another report is sent when the programming session ends.
Fire verify
Off
If this option is off, the panel immediately reports to the central station when a smoke 
detector goes into alarm.
With this option on, if a single smode detector goes into alarm the panel will not report 
for 60 seconds unless another smoke detector goes into alarm. If the first smoke 
detector is cleared of alarm with the first 60 seconds, no report will be sent to the 
central station unless it or a second smoke detector goes into alarm within the panel 
siren timeout period (5 minutes).
a.
Not investigated for use by UL.
Table 18. Reporting options (continued)
Function
Default
Description