UTC Fire & Security Americas Corporation Inc CGGAA3 Manual De Usuario

Descargar
Página de 8
 
6 / 8 
 
P/N 1069154U-F1 • REV 4.0 • ISS 05OCT12 
Resetting options 
To reset the detector to the default settings: 
1.  Remove the power from the detector. 
2.  Press and hold the programming button (see Figure 14, 
item 2). 
3.  Apply the power to the detector. 
4.  After the programming LED flashes, release the 
programming button. 
You can reset the detector either before installation, with a PP3 
battery, or by applying 12 V to the unit on site. 
Walk test 
In walk test mode, the blue detection LED option is set to ON, 
and the pulse count option is set to 1. The detection LED lights 
each time the DDI602U-F1 detects your presence. 
To enter the walk test mode, press the programming button 
once. The detection LED lights and pulse count 1 is 
automatically selected. The unit can then be aligned. The 
detection LED lights on the DDI602U-F1 every time detection 
takes place.  
The test mode ends automatically five minutes after last 
detection. Alternatively, press the program button three times, 
or remove and then reapply power to cancel the walk test 
mode. 
Note: 
When you conduct a walk test, make sure that the front 
cover is in place. Do not conduct walk tests with the cover 
removed. 
The range of the detector increases without the protective front 
cover. Therefore the front cover must be fitted to establish the 
correct beam pattern. Use Table 3 on page 5 to adjust the 
range as necessary. Pan and tilt the lens module over the field 
of view to obtain the correct coverage area. 
Accessories 
UTC Fire & Security can provide a handheld walk tester DI601-
WT to aid installations. 
Specifications 
Detection range 
Programmable: 10 m / 30 ft., 18 m / 59 ft., or 
25 m / 82 ft. 
Coverage  
10 to 70° detection angle, 30 x 24 m / 
98 x 79 ft. coverage max. 
Adjustment  
180° pan, 90° tilt 
Fresnel lens  
28 zones for each detection element, which 
can be masked with the curtain sliders 
Customized optics 
Double silicon shielded quad element 
eliminates 50,000 lux of white light 
LEDs 
Top red: Programming LED 
Red: PIR active 
Green: Microwave active 
Blue: Detector alarm 
Infrared: Walk tester communication 
Operating frequency 
10.525 GHz 
Outputs 
Silent, solid state, magnetically immune.  
 
NO 
Volt free relay, signal contact 24 VAC/DC at 
50 mA with an integral 25 Ω series resistor. 
Alarm time 5 seconds. 
 
NC 
Volt free relay, signal contact 24 VAC/DC at 
50 mA with an integral 25 Ω series resistor. 
Alarm time 5 seconds. 
Power input 
9 to 15 V
Current 
11 mA (12 V nominal) 
Pulse count 
1 or 2 
Temperature 
compensation 
Analogue (thermistor) and digital sensitivity 
adjustment 
Control 
Digital microprocessor with nonvolatile 
memory 
Walk test 
Output test mode with LED indication. 
Option to disable LEDs. 
Operating temperature 
−30 to +65°C / −22 to 149°F 
Housing 
High impact ABS plastic with HDPE cover, 
UV stabilized 
Dimensions, W x H x D 
125 x 175 x 130 mm / 4.92 x 6.89 x 5.12 in. 
Weight 
323 g net, 549 g gross / 11.39 oz net, 
19.37 oz gross 
Mounting height 
Variable up to 6 m / 20 ft.  
Optimum height 3 m / 10 ft. for full range 
Cable < 200 m / 656 ft. 
Utilising all three outputs (including tamper) 
— eight-core 7/0.2 mm² / 24 AWG 
Cable < 500 m / 1640 ft.  Utilising all three outputs (including tamper) 
— eight-core 16/0.2 mm² / 20 AWG 
Regulatory information 
Manufacturer 
UTC Fire & Security Americas Corporation, Inc. 
1275 Red Fox Rd., Arden Hills, MN 55112-6943, 
USA  
Authorized EU manufacturing representative: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 
Certification 
 
INCERT C0010502 
Environmental 
class 
IP65 
FCC compliance FCC ID:  B4Z-CGGAA3 
This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, 
and (2) this device must accept any interference 
received, including interference that may cause 
undesired operation. 
IC IC:1175C-GJDMOTION 
This Class B digital apparatus complies with 
Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme 
à la norme NMB-003 du Canada. 
European Union 
directives 
1999/5/EC (R&TTE directive): Hereby, UTC Fire & 
Security declares that this device is in compliance 
with the essential requirements and other relevant 
provisions of Directive 1999/5/EC.