UTC Fire & Security Americas Corporation Inc CGGAA3 Manual Do Utilizador
6 / 8
P/N 1069154U-F1 • REV 4.0 • ISS 05OCT12
Resetting options
To reset the detector to the default settings:
1. Remove the power from the detector.
2. Press and hold the programming button (see Figure 14,
item 2).
3. Apply the power to the detector.
4. After the programming LED flashes, release the
programming button.
You can reset the detector either before installation, with a PP3
battery, or by applying 12 V to the unit on site.
battery, or by applying 12 V to the unit on site.
Walk test
In walk test mode, the blue detection LED option is set to ON,
and the pulse count option is set to 1. The detection LED lights
each time the DDI602U-F1 detects your presence.
and the pulse count option is set to 1. The detection LED lights
each time the DDI602U-F1 detects your presence.
To enter the walk test mode, press the programming button
once. The detection LED lights and pulse count 1 is
automatically selected. The unit can then be aligned. The
detection LED lights on the DDI602U-F1 every time detection
takes place.
once. The detection LED lights and pulse count 1 is
automatically selected. The unit can then be aligned. The
detection LED lights on the DDI602U-F1 every time detection
takes place.
The test mode ends automatically five minutes after last
detection. Alternatively, press the program button three times,
or remove and then reapply power to cancel the walk test
mode.
detection. Alternatively, press the program button three times,
or remove and then reapply power to cancel the walk test
mode.
Note:
When you conduct a walk test, make sure that the front
cover is in place. Do not conduct walk tests with the cover
removed.
removed.
The range of the detector increases without the protective front
cover. Therefore the front cover must be fitted to establish the
correct beam pattern. Use Table 3 on page 5 to adjust the
range as necessary. Pan and tilt the lens module over the field
of view to obtain the correct coverage area.
cover. Therefore the front cover must be fitted to establish the
correct beam pattern. Use Table 3 on page 5 to adjust the
range as necessary. Pan and tilt the lens module over the field
of view to obtain the correct coverage area.
Accessories
UTC Fire & Security can provide a handheld walk tester DI601-
WT to aid installations.
WT to aid installations.
Specifications
Detection range
Programmable: 10 m / 30 ft., 18 m / 59 ft., or
25 m / 82 ft.
25 m / 82 ft.
Coverage
10 to 70° detection angle, 30 x 24 m /
98 x 79 ft. coverage max.
98 x 79 ft. coverage max.
Adjustment
180° pan, 90° tilt
Fresnel lens
28 zones for each detection element, which
can be masked with the curtain sliders
can be masked with the curtain sliders
Customized optics
Double silicon shielded quad element
eliminates 50,000 lux of white light
eliminates 50,000 lux of white light
LEDs
Top red: Programming LED
Red: PIR active
Green: Microwave active
Blue: Detector alarm
Red: PIR active
Green: Microwave active
Blue: Detector alarm
Infrared: Walk tester communication
Operating frequency
10.525 GHz
Outputs
Silent, solid state, magnetically immune.
NO
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
NC
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
Power input
9 to 15 V
Current
11 mA (12 V nominal)
Pulse count
1 or 2
Temperature
compensation
compensation
Analogue (thermistor) and digital sensitivity
adjustment
adjustment
Control
Digital microprocessor with nonvolatile
memory
memory
Walk test
Output test mode with LED indication.
Option to disable LEDs.
Option to disable LEDs.
Operating temperature
−30 to +65°C / −22 to 149°F
Housing
High impact ABS plastic with HDPE cover,
UV stabilized
UV stabilized
Dimensions, W x H x D
125 x 175 x 130 mm / 4.92 x 6.89 x 5.12 in.
Weight
323 g net, 549 g gross / 11.39 oz net,
19.37 oz gross
19.37 oz gross
Mounting height
Variable up to 6 m / 20 ft.
Optimum height 3 m / 10 ft. for full range
Optimum height 3 m / 10 ft. for full range
Cable < 200 m / 656 ft.
Utilising all three outputs (including tamper)
— eight-core 7/0.2 mm² / 24 AWG
— eight-core 7/0.2 mm² / 24 AWG
Cable < 500 m / 1640 ft. Utilising all three outputs (including tamper)
— eight-core 16/0.2 mm² / 20 AWG
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
INCERT C0010502
Environmental
class
class
IP65
FCC compliance FCC ID: B4Z-CGGAA3
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.
IC IC:1175C-GJDMOTION
This Class B digital apparatus complies with
Canadian ICES-003.
Canadian ICES-003.
Cet appareil numérique de la classe B est conforme
à la norme NMB-003 du Canada.
à la norme NMB-003 du Canada.
European Union
directives
directives
1999/5/EC (R&TTE directive): Hereby, UTC Fire &
Security declares that this device is in compliance
with the essential requirements and other relevant
provisions of Directive 1999/5/EC.
Security declares that this device is in compliance
with the essential requirements and other relevant
provisions of Directive 1999/5/EC.