Bosch Security Systems Inc. B116 Manual De Usuario

Descargar
Página de 10
FMR-500/RE-2 System   
 
Page 4 
 
Beltpack Transmitter. 
 
RF Power Output………………………….. 30 mW typical, Terminated. 
Antenna……………………………………..1/4 Wave flexible. 
Modulation, FM………………………………….40 KHz Deviation. 
Modulation Limiter…………………………Limiter/Compressor. 
Audio Input…………………………………7.75 mV for 40 KHz Deviation. 
    (77.5 mV for instruments). 
Power………………………………………..9.0 VDC (Alkaline). 
 
Handheld Transmitter. 
 
RF Power Output………………………….. 30 mW typical, Terminated. 
Antenna……………………………………..Internal ½ Wave Dipole. 
Modulation, FM………………………………….40 KHz Deviation. 
Modulation Limiter…………………………Limiter/Compressor. 
Audio Input…………………………………395 mV for 40 KHz Deviation. 
Power………………………………………..9.0 VDC (Alkaline).       
 
SYSTEM PROGRAMMING/OPERATION 
 
The FMR-500/RE-2 System uses the same basic programming steps in the 
Receiver and Transmitters. Learning these basic steps early will save time 
and effort. Read the following section then proceed to the Set-Up Section. 
 
Receiver: 
 
Note:
 The FMR-500/RE-2 receiver is supplied with a “Secure” or lockout 
function. All of the “buttons” can be secured to prevent accidental operation 
or tampering. If the Set switch is pressed in Secure Mode, “Loc-Out” will 
appear on the screen. If the Up or Dow buttons are pressed in Secure Mode, 
nothing happens. Pressing the power button in Secure Mode will not turn the 
receiver off. To unlock the buttons, Press and Hold the Up and Down 
buttons for 3 seconds. ACC.ESS will appear as long as the buttons are held. 
To re-lock the receiver, press the Up and Down buttons for 3 seconds until 
Sec.uRE is displayed.