Unit Description, CXU-10
The CXU is also connected to a CDU-bus. By sending data through the
CDU-Bus, the switches can be set to fulfil one of six supported
configurations.
Inside the CXU there are also some splitters to distribute the incoming
RX-signals to the switches and in some cases directly to an out port.
The RF cables between CDU and CXU are supervised in the CXU. The
RF cables between CXU and dTRU are supervised in the dTRU.
The CDU-bus cable is monitored by the DXU.
9.3
External Interfaces
The CXU has the following connectors:
Six inputs for RX signals from the CDU
Twelve output ports for RX signals to dTRU
CDU-bus connector for alarm and configuration settings
Power supply connector
The CXU has the following indicators:
Operational – green
Fault – red
RXI TRU1 RX2
RXI CDU RX2
RXI TRU2 RX2
RXI TRU3 RX2
RXI TRU4 RX2
RXI CDU2 RX2
RXI TRU5 RX2
RXI CDU3 RX2
RXI TRU6 RX2
Oper Fault
DC/CD U3 CDU bus
CXU-10
900
P007458A
Figure 73
CXU-10, external interfaces
9.4
Technical Data
Table 84
Technical data
Height
22 mm
Width
482.6 mm
Depth
120 mm
1)
Weight
2 kg
Max. power consumption
10 W
1)
The CXU protrudes 40 mm in front of the magazine.