Ericsson Radio Systems AB PKRC1311004-1 Manual De Usuario

Descargar
Página de 423
Operation and Maintenance Support
Table 121
Operational States
RU in Remote Mode
RU in Local Mode
The state of the operational indicator on
CMRU and TDMRU is determined upon
the operational mode of the MOs
associated to the RU. The operational
indicator on the EDMRU is only controlled
locally and is described by the Diagnostics
and Fault Handling Functionality.
The master cabinet is considered
Operational if SO CF and at least one SO
TRXC are considered free from class 1
HW faults and Local Configuration has
been performed.
The MO operational mode is reported by
the BSC with the
OPERATIONAL_INFORMATION
message. An MO is internally taken out of
operation at reset (refer to the Function
Change Functionality) or when its
associated RU is taken into Local Mode.
A Sub-RU is considered Operational if
there are no class 1 faults on the RU.
The Extension Cabinet (if there is any) is
considered operational if at least one SO
TRXC is considered free from class 1
HW faults and Local Configuration has
been performed.
The Master Cabinet is considered
operational if SO CF, at least one SO
TRXC, at least one AO RX and at least
one AO TS are considered operational by
the BSC, set by the message
OPERATIONAL _INFORMATION to each
MO.
The Remote Operational Indication
function is terminated when
OPERATIONAL_INFORMATION_ACCEPT
is sent on the Abis interface.
The TDMRU is considered Operational
when SO TRXC, AO RX and at least one
AO TS are considered Operational by the
BSC, set by the message
OPERATIONAL_INFORMATION to each
MO. In the case of SW Power Boost
configuration the OPERATIONAL indicator
on the TDMRU implementing the slave TX
is on when the indicator on the master
TDMRU is on. Otherwise, the indicator is
off.
The Remote Operational Indication
function and the Operational Information
function are terminated when
OPERATIONAL_INFORMATION_ACCEPT
is sent on the Abis interface.
Note:
The CMRU and the TDMRU is considered Not Operational
during change of RU Mode. The EDMRUs and sub-RUs
are always in Local Mode. Only the CMRU and the
TDMRUs can be in Remote Mode.
38.16
Tx Not Enabled Indicator
Purpose
To indicate that TX is not enabled.
294 (421)
EN/LZT 720 0008
R1A
2001-06-26
© Ericsson Radio Systems AB
— All Rights Reserved —