Operation and Maintenance Support
For a TDMRU that is configured to implement a
slave TX in a SW Power Boost configuration:
The RU is remote via the TDMRU that
implements the master TX.
For description of changing an RU to Local Mode, see Section 38.4
Change RU to Local Mode on page 285.
Limitations:
The Local Mode indicator will not indicate when the layer 2 A-bis
communication with the BSC is lost when the RU Mode is Remote.
38.18
External Alarms Indicator
Purpose
To indicate if any external alarm defined by the operator is active.
Preconditions and Initiation
Applicable for any operational condition. The function is initiated when
the SW is started. The functionality is initiated when the RBS DB has
been read during the start-up sequence (refer to Restart and Recovery
functionality).
Description
The External Alarms indicator indicates if any external alarm defined by
the operator is active. The External Alarm Indicator is controlled from
External Alarms functionality and from Restart and Recovery
functionality. When the RU is reset in any way the handling of the
indicator is terminated.
Colour:
Yellow
Position:
CMRU (DXU)
States of the indicator
ON:
Any external alarm connected to an inlet
in this cabinet is active.
FLASHING (0.5 Hz):
Any external alarm connected to an inlet
in an extension cabinet is active.
OFF
No external alarm connected to an inlet in
any cabinet is active.
38.19
DC Disconnected Indicator
Purpose
To indicate if the DC is disconnected.
296 (421)
EN/LZT 720 0008
R1A
2001-06-26
© Ericsson Radio Systems AB
— All Rights Reserved —