Table 5 – Andrew Connectors
7.1 RF Cable Installation
RF cables should normally be placed in conduit or cable trays. Where
this is not possible the Heliax cable should be supported every 24 ". The
Systems Engineer must determine if cabling meets Fire Regulations and
Building codes. Notify the System Engineer of deviations in cable
routing from the System design document .
this is not possible the Heliax cable should be supported every 24 ". The
Systems Engineer must determine if cabling meets Fire Regulations and
Building codes. Notify the System Engineer of deviations in cable
routing from the System design document .
Table 6 –Heliax Minimum Bending Radius
Connector Description
CPC
Manufacturer
For Use with
Comments
0.25
″
N-Male: 41PW
A0382258
Andrew
0.25
″
Coax
0.375
″
N-Male: L42PW
A0621669
Andrew
0.375
″
Coax
Use with LDF cables
0.375
″
N-Male: 42SPW
A0621669
Andrew
0.375
″
Coax
Use with Superflex
cables
0.5
″
N-Male: L44PW
A0615483
Andrew
0.5
″
Coax
Use with LDF cables
0.5
″
N-Male: 44SEW
A0381727
Andrew
0.5
″
Coax
Use with Superflex
cables
50W termination, Male:
50T-007
A0609689
JFW
Hybrids
Terminating unused
ports of the hybrids
Adapter N-Female to
N- Female
A0600384
Andrew
Connecting Jumper to
Co-ax cable
Cable
Nominal
diameter
Diameter
over jacket
Minimum
bending
radius
FSJ1-50A
1/4"
.29"
1"
ETS1-50T
1/4"
.29"
1"
LDF2-50
3/8"
.44"
3.75"
ETS2-50T
3/8"
.415"
1"
FSJ4-50B
1/2"
.52"
1.25"
LDF4-50A
1/2"
.63"
5"
FT4-50T
1/2"
.60"
5"