7.0  Cable Types and Connectors
Andrew cables and connectors are recommended for use throughout the 
Picocell 1900  antenna system.  One exception is the Huber-Suhner  
Jumper at the Picocell 1900 transceiver.   The tables below lists 
recommended connector and cable types.  The Andrew Corporation  
connector catalog numbers, Nortel CPC part number, manufacturer  and 
insertion loss is listed below. Circumstances may result in equivalent 
cable types being specified or sourced from other manufacturers. Use 
the original Equipment Manufacturer’s (OEM) instructions supplied 
with the connectors for assembly.
The N(m) to TNC(m) jumper connects the main transmission line to the 
Picocell 1900 transceiver which requires a flexible cable for entry.
Table 4 – Andrew Cable Types and Insertion Loss 
Cable Description
CPC
Manufacturer
Loss
a
 (dB/
100m)
a.
AT 2 GHz, VSWR 1.0, ambient temperature 24°C. Losses does not include Connector Losses
0.25
 Foam Superflex: FSJ1-50A
R0116633
Andrew
28.6
0.25
 Plenum, Foam Superflex: ETS1-50T
R0116910
Andrew
28.0
0.375
 Foam: LDF2-50
R0116726
Andrew
17.1
0.5
 Foam: LDF4-50A
R0116728
Andrew
11.3
0.5
 Foam Superflex: FSJ4-50B
R0116634
Andrew
17.7
0.5
 Plenum, Foam: FT4-50T
R0116883
Andrew
20.3
RF Antenna Cable (TNC male to N-Male)
(This is a Jumper cable 1.8 m long and 
1.5 dB attenuation)
B0241275
Huber Suhner 
75.0