Method 12-0152
Draft
manually flared against the clamping nut.  Proceed to Paragraphs 9g and 
9h for flaring the 3/8" and 1/2" cable/connector assemblies.
10.
Clean the foam off the inner conductor with a knife.  Be careful not to 
scrape the inner conductor.  Use the garnet cloth to remove the adhesive 
and to ensure that the surface is clean.
Note:  The surface must be residue free, leftover foam can interfere with 
setting the pin on the conductor and can reduce conductivity.
Figure 12 – Outer Sheath Stripping Lengths
Table 8 –Outer Seath Strip Length
.
Figure 13 – . Cable With O Ring
Cable description
Cable #
Distance
1/4" Heliax superflexible standard jacket
FSJ1-50A
7/8"
1/4" Heliax superflexible plenum
ETS1-50T
7/8"
3/8" Heliax foam dielectric standard jacket
LDF2-50
1 1/4"
3/8" Heliax foam dielectric superflexible, ple-
num
ETS2-50T
1 1/2"
1/2" Heliax superflexible standard jacket
FSJ4-50B
1 1/2"
1/2" Heliax foam dielectric standard jacket
LDF4-50A
2"
1/2" Heliax foam dielectric plenum
FT4-50T
2"
amount of jacket to be removed