Avaya Canada Corporation NTMQ75AA Manual De Usuario
Picocell 1900 Antenna System Installation / 27
September 4, 1998
Method 12-0152
Draft
manually flared against the clamping nut. Proceed to Paragraphs 9g and
9h for flaring the 3/8" and 1/2" cable/connector assemblies.
9h for flaring the 3/8" and 1/2" cable/connector assemblies.
10.
Clean the foam off the inner conductor with a knife. Be careful not to
scrape the inner conductor. Use the garnet cloth to remove the adhesive
and to ensure that the surface is clean.
scrape the inner conductor. Use the garnet cloth to remove the adhesive
and to ensure that the surface is clean.
Note: The surface must be residue free, leftover foam can interfere with
setting the pin on the conductor and can reduce conductivity.
setting the pin on the conductor and can reduce conductivity.
Figure 12 – Outer Sheath Stripping Lengths
Table 8 –Outer Seath Strip Length
.
Figure 13 – . Cable With O Ring
Cable description
Cable #
Distance
1/4" Heliax superflexible standard jacket
FSJ1-50A
7/8"
1/4" Heliax superflexible plenum
ETS1-50T
7/8"
3/8" Heliax foam dielectric standard jacket
LDF2-50
1 1/4"
3/8" Heliax foam dielectric superflexible, ple-
num
ETS2-50T
1 1/2"
1/2" Heliax superflexible standard jacket
FSJ4-50B
1 1/2"
1/2" Heliax foam dielectric standard jacket
LDF4-50A
2"
1/2" Heliax foam dielectric plenum
FT4-50T
2"
amount of jacket to be removed