Avaya Canada Corporation NTMQ75AA Manual De Usuario
Picocell 1900 Antenna System Installation / 29
September 4, 1998
Method 12-0152
Draft
Table 9 – Outer Conductor Trim Lengths
Figure 17 – Center Conductor Finishing
Figure 18 – Size The Inner Conductor
Cable description
Cable #
Connector
Amount
showing
1/4" Heliax superflexible standard jacket
FSJ1-50A
F1PNM-HF
(41PW)
1/16"
1/4" Heliax superflexible plenum
ETS1-50T
F1PNM-HF
(41PW)
1/16"
3/8" Heliax foam dielectric standard jacket
LDF2-50
L2PNM
(L42PW)
flush
3/8" Heliax foam dielectric superflexible,
plenum
ETS2-50T
F2PNM
(42SPW)
1/32"
1/2" Heliax superflexible standard jacket
FSJ4-50B
F4PNM
(44SEW)
1/16"
1/2" Heliax foam dielectric standard jacket
LDF4-50A
L4PNM
(L44PW)
flush
1/2" Heliax foam dielectric plenum
FT4-50T
L4PNM
(L44PW)
flush
inner conductor – make sure it is clean
deburr the end