Avaya Canada Corporation NTMQ75AA Manual De Usuario

Descargar
Página de 35
30 / Picocell 1900 Antenna System Installation
 Method 12-0152
September 4, 1998
Draft
Table 10 –Center Conductor Trim Length
Figure 19 – Cable/Clamping Nut
Cable description
Cable #
Connector
Inner 
conductor 
length
1/4" Heliax superflexible standard jacket
FSJ1-50A
F1PNM-HF 
(41PW)
1/4"
1/4" Heliax superflexible plenum
ETS1-50T
F1PNM-HF 
(41PW)
1/4"
3/8" Heliax foam dielectric standard jacket
LDF2-50
L2PNM         
(L42PW)
3/16"
3/8" Heliax foam dielectric superflexible, ple-
num
ETS2-50T
F2PNM       
(42SPW)
7/32"
1/2" Heliax superflexible standard jacket
FSJ4-50B
F4PNM       
(44SEW)
3/16"
1/2" Heliax foam dielectric standard jacket
LDF4-50A
L4PNM      
(L44PW)
7/32"
1/2"  Heliax  foam  dielectric  plenum
FT4-50T
L4PNM        
(L44PW)
7/32"
cross-section of the cable and 
clamping nut
AA
AA
AA
AA
AA
AA
AA
AA
AA
AA