Table 10 –Center Conductor Trim Length
Figure 19 – Cable/Clamping Nut
Cable description
Cable #
Connector
Inner
conductor
length
1/4" Heliax superflexible standard jacket
FSJ1-50A
F1PNM-HF
(41PW)
1/4"
1/4" Heliax superflexible plenum
ETS1-50T
F1PNM-HF
(41PW)
1/4"
3/8" Heliax foam dielectric standard jacket
LDF2-50
L2PNM
(L42PW)
3/16"
3/8" Heliax foam dielectric superflexible, ple-
num
ETS2-50T
F2PNM
(42SPW)
7/32"
1/2" Heliax superflexible standard jacket
FSJ4-50B
F4PNM
(44SEW)
3/16"
1/2" Heliax foam dielectric standard jacket
LDF4-50A
L4PNM
(L44PW)
7/32"
1/2" Heliax foam dielectric plenum
FT4-50T
L4PNM
(L44PW)
7/32"