desired search band, then repeatedly press ^ or v. L-r (Lockout Review) appears and the 
scanner displays all locked out frequencies as you press ^ or v, or, EMPty appears when the 
search band has no locked out frequencies. When you reach the highest locked-out 
frequency, the scanner beeps twice and returns to the lowest locked-out frequency. 
 
If you press CLEAR using lock out frequency review, the lockout of the frequency is cleared. 
 
Removing Lockouts Form All Frequencies in a Search Band 
 
1. Press FUNC then CLEAR during a desired search band. L-r appears. 
 
2. FLo ALL-CL appears about 2 seconds. After 2 seconds, YES ---Ent and No ---CLEAr 
appears alternately. 
 
3. Press ENT. L-r EMPty appears. The scanner clears any lockouts from all frequencies in a 
search band. Or, if you do not want to clear the lockouts, press CLEAR. 
 
USING PRIORITY 
 
The priority feature lets you scan through channels and still not miss important or interesting 
calls on a frequency you select. You can program one frequency into the priority channel. As 
the scanner scans, if the priority feature is turned on, the scanner checks the priority channel 
for activity every 2 seconds. 
 
1. Press PGM, then press PRI while SCAN mode. PCH and 000.0000 or the 
previously-stored frequency appears. 
 
2. Enter the frequency you want to enter into the priority channel, then press ENT. The 
display flashes twice. 
 
To program a weather channel as the priority channel: 
 
1. Press WX. 
 
2. Select the weather channel you want to program as the priority channel. 
 