•  Under the File pull down, select Import, browse to the Seal specific .hex file for the 
Seal and select Open.  The program will report the successful import of the hex file. 
•  Click Programmer from the top menu line and click on Program in the drop-down 
menu 
 
•  The progress bar at the bottom of the screen will indicate that programming is in 
progress, and the screen will report “Programming/Verify Complete” when it is 
finished.  Exit the MPLAB IDE program. 
2.1.4  Writing the Hex File to the Seal with PICKit2 
Writing the .hex file to the Seal requires the RMSA USB/Programmer.  To write the .hex file to 
a Seal, perform the following steps: 
•  Select a Seal, remove  the enclosure and connect the RMSA USB/Programming 
dongle and PICKit 2 dongle shown in Section 2.1 of this User Guide.   
•  Start the PICKit 2 application.  Once started, the PICKit 2 window should indicate that 
a PIC device was found.  If not, check dongle cabling (as shown in Section 2.1) and 
repeat this step until the connection is indicated. 