6.2 BMDware Pin Functions
Rigado BMDware is programmed on the BMD-300 Series at the factory. BMDware provides UART-to-BLE Bridge,
beaconing, and Direct Test Mode (DTM) functionality. The pins in Table 5 below describe the pin functionality in
BMDware. DTM Mode, Beacon-Only Mode, and AT Command Mode pin states are checked at BMDware start-up
to configure BMDware as required by the user, and are then set to Hi-Z to conserve power. For further details on
BMDware operation, please see the BMDware Datasheet that can be found at
beaconing, and Direct Test Mode (DTM) functionality. The pins in Table 5 below describe the pin functionality in
BMDware. DTM Mode, Beacon-Only Mode, and AT Command Mode pin states are checked at BMDware start-up
to configure BMDware as required by the user, and are then set to Hi-Z to conserve power. For further details on
BMDware operation, please see the BMDware Datasheet that can be found at
. BMDware can be
overwritten by RigDFU with custom application firmware, or removed along with RigDFU by a full chip erase.
Pin
Name Direction
BMDware Functions
21
P0.05
Out
Bridge UART RTS
Disabled in Beacon-Only & DTM modes, N/C if not used.
22
P0.06
Out
Bridge UART TX
Disabled in Beacon-Only & DTM modes, N/C if not used.
23
P0.07
In
Bridge UART CTS
Disabled in Beacon-Only & DTM modes, N/C if not used.
24
P0.08
In
Bridge UART RX
Disabled in Beacon-Only & DTM modes, N/C if not used.
Disabled in Beacon-Only & DTM modes, N/C if not used.
27
P0.11
Out
DTM UART TX
Only enabled in DTM mode; N/C if not used.
28
P0.12
In
DTM UART RX / DTM Mode
Only enabled in DTM mode; N/C if not used.
On BMDware Start-up:
High = Enter DTM mode; Low = Enter Normal Operation
Internal 12kΩ pull-down during BMDware start-up, then Hi-Z
On BMDware Start-up:
High = Enter DTM mode; Low = Enter Normal Operation
Internal 12kΩ pull-down during BMDware start-up, then Hi-Z
31
P0.13
In
Beacon Only Mode
On BMDware Start-up:
High = Bridge UART enabled; Low = Bridge UART disabled
Internal 12kΩ pull-up during BMDware start-up, then Hi-Z
High = Bridge UART enabled; Low = Bridge UART disabled
Internal 12kΩ pull-up during BMDware start-up, then Hi-Z
32
P0.14
In
UART AT Command Mode
On BMDware Start-up:
High = Full pass-through mode; Low = AT command mode
Internal 12kΩ pull-up during BMDware start-up, then Hi-Z
On BMDware Start-up:
High = Full pass-through mode; Low = AT command mode
Internal 12kΩ pull-up during BMDware start-up, then Hi-Z