Fibar Group S.A. FGDW002 Manual De Usuario
10
ADVAnCED PARAMETERS
#7: Advanced parameters
The Door/Window Sensor 2 allows to customize its operation to user’s
needs. Settings are available in the FIBARO interface as simple op-
tions that may be chosen by selecting the appropriate box.
In order to configure the Door/Window Sensor 2 (using
In order to configure the Door/Window Sensor 2 (using
the Home Center controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced” tab.
1. Go to the device options by clicking the icon:
2. Select the „Advanced” tab.
1. Door/window state
This parameter allows to set in what state is door/window when the
This parameter allows to set in what state is door/window when the
magnet is close to the sensor.
Available settings: 0 - closed when magnet near
1 - opened when magnet near
Default setting:
0
Parameter size:
1 [byte]
2. Visual LED indications
This parameter defines events indicated by the visual LED indicator.
This parameter defines events indicated by the visual LED indicator.
Disabling events might extend battery life.
Available settings: 1 - indication of opening/closing status change
2 - indication of wake up (1 x click or periodical)
4 - indication of device tampering
4 - indication of device tampering
Default setting:
6
Parameter size:
1 [byte]
Wake up interval
Available settings: 0 or 3600-64800 (in seconds (1-18h), 3600s (1h)
Available settings: 0 or 3600-64800 (in seconds (1-18h), 3600s (1h)
step)
Default setting: 21600 (6h)
The Door/Window Sensor will wake up after each defined time inter-
Default setting: 21600 (6h)
The Door/Window Sensor will wake up after each defined time inter-
val and always try to connect with the main controller. After a suc-
cessful communication attempt, the sensor will update configuration
parameters, associations and settings and will go into standby mode.
After failed communication attempt (e.g. lack of Z-Wave range) the
device will go into standby mode and retry to establish connection
with the main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake Up notification
Setting wake up interval to 0 disables sending Wake Up notification
frame automatically. Wake up may be still performed manually by a
clicking one of the TMP buttons (while the other button is pressed).
Longer time interval means less frequent communication and thus a
Longer time interval means less frequent communication and thus a
longer battery life.
NOTE
Entering invalid value
of parameter will re-
sult in response with
Application Rejected
frame and not setting
the value.
of parameter will re-
sult in response with
Application Rejected
frame and not setting
the value.
i
NOTE
Parameter 2 values
may be combined, e.g.
1+2=3 means that in-
dications for opening/
closing and waking up
are enabled.
may be combined, e.g.
1+2=3 means that in-
dications for opening/
closing and waking up
are enabled.
i