Fibar Group S.A. FGDW002 Manual De Usuario

Descargar
Página de 16
10
ADVAnCED PARAMETERS
#7: Advanced parameters
The Door/Window Sensor 2 allows to customize its operation to user’s 
needs. Settings are available in the FIBARO interface as simple op-
tions that may be chosen by selecting the appropriate box.
In order to configure the Door/Window Sensor 2 (using 
 
the Home Center controller):
1.  Go to the device options by clicking the icon:   
2.  Select the „Advanced” tab.
1. Door/window state
This parameter allows to set in what state is door/window when the 
magnet is close to the sensor.
Available settings: 0 - closed when magnet near
1 - opened when magnet near 
Default setting: 
0
Parameter size:
1 [byte]
2. Visual LED indications
This parameter defines events indicated by the visual LED indicator. 
Disabling events might extend battery life.
Available settings: 1 - indication of opening/closing status change
2 - indication of wake up (1 x click or periodical)
4 - indication of device tampering
Default setting: 
6
Parameter size:
1 [byte]
Wake up interval
Available settings: 0 or 3600-64800 (in seconds (1-18h), 3600s (1h) 
step)
Default setting: 21600 (6h)
The Door/Window Sensor will wake up after each defined time inter-
val and always try to connect with the main controller. After a suc-
cessful communication attempt, the sensor will update configuration 
parameters, associations and settings and will go into standby mode. 
After failed communication attempt (e.g. lack of Z-Wave range) the 
device will go into standby mode  and retry to establish connection 
with the main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake Up notification 
frame automatically. Wake up may be still performed manually by a 
clicking one of the TMP buttons (while the other button is pressed).
Longer time interval means less frequent communication and thus a 
longer battery life.
NOTE
Entering invalid value 
of parameter will re-
sult in response with 
Application Rejected 
frame and not setting 
the value.
i
NOTE
Parameter 2 values 
may be combined, e.g. 
1+2=3 means that in-
dications for opening/
closing and waking up 
are enabled.
i