ASSOCIATIOn
#6: Association
The Door/Window Sensor 2 provides the association of three 
groups:
1st Association Group – “Lifeline”
 reports the device status and al-
lows for assigning single device only (main controller by default).
2nd Association Group –  “On/Off” is assigned to the device status - 
Hall effect sensor (sends Basic Set command frames).
3rd Association Group – “Tamper” is assigned to the TMP switch 
(sends alarm command frames).
To add an association (using the Home Center controller):
1.  Go to device options by clicking the icon: 
2.  Select the „Advanced” tab.
3.  Specify to which group and what devices are to be associated.
4.  Save the changes.
5.  Wake up the device manually or wait for the next automatic wake 
up.
NOTE
Association allows 
transfer of control 
commands between 
devices without par-
ticipation of the main 
controller. 
Direct range between 
devices is recom-
mended.
i
The Door/Window Sensor 2 in 2nd and 3rd group allows to control 
5 devices (regular or multichannel) per an association group. 
 
“LifeLine” group is reserved solely for the controller and hence only 1 
node can  be assigned.
Association (linking devices) - direct control of other devices within 
the Z-Wave system network e.g. Dimmer, Relay Switch, Roller Shutter 