2.3  Test A BMM 
The Test button confirms a BMM works. 
•  Position the Activator within 100 mm (or 3”) and 
press  the  grey 
TEST 
button 
❼  (the  display  ❹ 
can be any number). The most effective way is to 
position  the  Activator  as  demonstrated  in  the 
photo (by resting the activator on the BMM). The 
Activator  LEDs  illuminate  for  about  5  seconds 
and then turn off.  
•  It is not necessary to Test each BMM. 
 
2.4  Set a Transmit Delay 
•  In BAT mode, (BAT LED is green) press the yellow 
+1
 or 
+10
 buttons 
❸ to select the desired 
start-up delay. The +1 button sets the delay in increments of 1 hour, up to a maximum of 99 
hours. The +10 button sets the delay in multiples of 10 hours, up to a maximum of 90 hours. 
The display 
❹ shows the delay in hours. 
•  In Normal mode, (Normal LED is green) press the yellow 
+1 
button 
❸ to select the desired 
start-up  delay  time  in multiples  of  4  hours,  up  to  a maximum  of  36  hours. The  display 
❹ 
shows the actual delay in hours
.  
 
2.5  About the Transmit Delay 
•  A BMM transmits at constant power for 10 – 12 hours.  
•  To accurately calculate the depth of a BMM after the blast, it should be located within 12 
hours since activation. A BMM transmits for about 24 hours but the signal slowly decrease 
and eventually  it  switches off. If BMM is located after the initial  10-hr period, its horizontal 
location is accurate but not its depth.  
•  The delay feature was specifically designed for mines that could not access the muckpile 
immediately after blasting due to light and/or safety reasons. 
 
2.5.1  Delay in Normal Mode 
•  When a transmit delay is set in Normal mode, the BMM will transmit for approximately 15 
minutes before switching off and sleeping for the requested delay period. At the end of the 
delay period, it will transmit normally until the battery runs out of power.  
 
•  Calculate the delay, in hours, from the time the BMMs are installed in a blast to the BMMs 
transmitting. Refer to the 
“Monitoring Procedure Manual” for more information about how the 
transmit delay may be used. 
 
Place the Activator on the BMM; press TEST to check if 
a BMM works.