BW Broadcast Ltd TX300V2 Manual De Usuario
TX V2 FM Broadcast Transmitter
Menu Map
23
Menu Map
•
RF Settings
o
Frequency Sets the transmission frequency. This parameter accepts values from 87500000 to
108000000.
108000000.
o
Power Sets the output power level in watts. This parameter accepts values from 0 to 3000.
o
MPX Source Selects the source for the exciter. - Internal: selects internal generator. - External:
selects MPX BNC input.
selects MPX BNC input.
o
FSK Sets interval between FSK messages.
o
FSK ID Sets the FSK text. This will be converted into Morse code. Accepts text of up to 16
characters.
characters.
o
RF Mute on Silence Selects the time after which the transmitter’s output will be muted if the
input fails.
input fails.
o
RF Mute (Manual) Manually mutes the transmitter.
•
Audio Settings
o
MPX Source Selects the source for the exciter. - Internal: selects internal generator. - External:
selects MPX BNC input.
selects MPX BNC input.
o
Audio Input Selects the input source.
o
Processing Preset Loads the audio processing preset.
o
Pre-emphasis Sets the pre-emphasis.
o
Audio Mode Selects mono or stereo.
•
Triggers
o
Trigger [1-4]
o
Enable Enables/disables the trigger.
o
Action Determines the action performed upon trigger.
o
Send e-mail Selects if an e-mail will be sent when the alarm state changes.
o
(ON) Message Sets the message that will be sent when the Trigger changes to ON. Accepts
text of up to 300 characters.
text of up to 300 characters.
•
Alarms
o
Alarm [A-C]
o
Source Selects which detector is the source for the alarm. Options are Modulation, Fwd
Power, Rev Power and PLL lock fail.
Power, Rev Power and PLL lock fail.
o
Modulation Threshold Selects the threshold at which the modulation level alarm will be
activated. This parameter accepts values from 1000 to 100000.
activated. This parameter accepts values from 1000 to 100000.
o
Fwd Power Threshold / Rev Power Threshold Sets the threshold at which the forward power
alarm will be activated. This parameter accepts values from 0 to 2000.
alarm will be activated. This parameter accepts values from 0 to 2000.
o
Pin Polarity Selects whether the output is active high or active low.
o
On Delay Sets how long the error condition must occur for before an alarm is triggered. This
parameter accepts values from 2 to 600.
parameter accepts values from 2 to 600.
o
Off Delay Sets how long the error condition must have stopped for before an alarm is un-
triggered. This parameter accepts values from 2 to 600.
triggered. This parameter accepts values from 2 to 600.
o
Send e-mail Selects if an e-mail will be sent when the alarm state changes.
•
System
o
Date Sets the date of the Real Time Clock. Accepts date in format dd/mm/yy.
o
Time Sets the time of the Real Time Clock. Accepts time in format hh:mm.
o
Uptime Reports the uptime of the unit (i.e. how long has it been powered on for). Accepts text
of up to 20 characters.
of up to 20 characters.
o
Location The physical location of this device (e.g., ‘telephone closet, 3rd floor’). Accepts text of
up to 64 characters.
up to 64 characters.
o
Contact The contact details for the person who manages this device. Accepts text of up to 64
characters.
characters.
o
Screen Saver This allows the time-out before the screensaver starts to be adjusted between
15s and 30 minutes.
15s and 30 minutes.
o
Screen Lock Enables/disables the screen lock code.
o
Screen Lock Code Sets the screen lock code. Accepts text of up to 8 characters.
o
Users
Username The username for the remote login. Accepts text of up to 15 characters.
Password The password for the remote login. Accepts text of up to 15 characters.
o
Ethernet
DHCP Sets whether the Ethernet is configured manually or by DHCP.
DHCP IP Reads back the DHCP IP address. Accepts IPv4 address in the form
123.456.789.123.
123.456.789.123.
DHCP SM Reads back the DHCP subnet mask. Accepts IPv4 address in the form
123.456.789.123.
123.456.789.123.
DHCP GW Reads back the DHCP gateway. Accepts IPv4 address in the form
123.456.789.123.
123.456.789.123.