DCV-00001 Rev 05 S2 G6 OPT Installation Guide 
 
Page 18 
 
4.5.4  Main Power Supply Wiring 
The  other  end  of  the  low-voltage  DC  Cable  is  connected  into  the  AC-DC  power  supply  as 
below: 
 
 
Note: If retrofitting in place of a G5 OPT, the power supply may be able to be re-used. In this 
case the old 24V DC cable that powered the G5 OPT must be disconnected and replaced 
with the new cable for the G6 OPT. 
 
WARNING 
– Once all the wiring to the power supply terminals has been completed, 
install the terminal cover to prevent accidental contact with the live mains connections. 
4.5.5  Wiring Completion 
When all the cables have been installed, use cable ties to provide strain relief. The rear of the 
G6 OPT has two plastic loops close to the connectors that are intended to assist with this. 
Also ensure that all cables are tidy and cannot become snagged or pinched when the door of 
the cabinet is opened and closed. 
WARNING 
–  Local  regulations  may  also  require  that  the  installation  is  electrically 
tested and certified BEFORE switch-on.