BEIJING STRONGLINK TECHNOLOGY CO . LTD. SL30120P Manual De Usuario

Descargar
Página de 18
StrongLink
SL030 3.1
http://www.stronglink-rfid.com
13
Key:
Authentication key written if the operation succeeds, 6 bytes.
Attention: Be sure KeyB is readable, otherwise KeyB will be change to 000000000000
after this command.
4-3-10. Increment value
Host Write:
Len
0x08
Block
Value
Block: The absolute address of block to be increased, 1 byte.
Value: The value to be increased by, 4 bytes.
Host Read:
Len
0x08
Status
Value
Status: 0x00: Operation succeed
0x01: No tag
0x05: Write fail
0x06: Unable to read after write
0x0D: Not authenticate
0x0E: Not a value block
Value: The value after increment if the operation succeeds, 4 bytes
4-3-11. Decrement value
Host Write:
Len
0x09
Block
Value
Block: The absolute address of block to be decreased, 1 byte
Value: The value to be decreased by, 4 bytes
Host Read:
Len
0x09
Status
Value
Status: 0x00: Operation succeed
0x01: No tag
0x05: Write fail
0x06: Unable to read after write
0x0D: Not authenticate
0x0E: Not a value block
Value: The value after decrement if the operation succeeds, 4 bytes
4-3-12. Copy value
Host Write:
Len
0x0A Source
Destination
Source:
The source block copy from, 1 byte
Destination: The destination copy to, 1 byte
The source and destination must in the same sector
Host Read:
Len
0x0A Status
Value
Status: 0x00: Operation succeed