0x01: No tag
0x05: Write fail
0x06: Unable to read after write
0x0D: Not authenticate
0x0E: Not a value block (Source)
Value: The value after copy if the operation succeeds, 4 bytes
4-3-13. Read a data page (UltraLight & NTAG203)
Host Write:
Len
0x10
Page
Page: The page number to be read, 1 byte
Host Read:
Len
0x10
Status
Data
Status: 0x00: Operation succeed
0x01: No tag
0x04: Read fail
0x08: Address overflow
Data:
Block data returned if operation succeeds, 4 bytes.
4-3-14. Write a data Page (UltraLight & NTAG203)
Host Write:
Len
0x11
Page
Data
Page: The page number to be written, 1 byte.
Data:
The data to write, 4 bytes.
Host Read:
Len
0x11
Status
Data
Status: 0x00: Operation succeed
0x01: No tag
0x05: Write fail
0x06: Unable to read after write
0x08: Address overflow
Data:
page data written if operation succeeds, 4 bytes.
4-3-15. Request for Answer to Select (ISO14443-4)
Len
0x20
Response:
Len
0x20
Status
ATS
Status: 0x00: Operation succeed
0x10: Address overflow
ATS:
According to ISO14443-4 protocol
Len + T
0
+ TA
1
+ TB
1
+ TC
1
+ A
1
+ A
K
4-3-16. Exchange Transparent Data (T = CL)
Len
0x21
Data