innogy SE IEKA160 Manual De Usuario
Technical Information
LSX
24
4.3.14
X15
–
GFI connection charging point 1
GFI connection for charging point 1 takes place using socket X15.
Property
Value
Socket
Molex MicroFit 43045-0601
Table 30: Technical Information – GFI connection charging point 1
Property
Value
Signal
GFI_Preset
Execution
Open collector output (to GND)
Load
max. 12 V DC at 25 mA
Voltage drop condition 1
max. 1 V DC at 10 mA
Leakage current condition 0
> 50 mA
Table 31: Technical Information – GFI connection charging point 1 – GFI_Preset
Property
Value
Signal
GFI_Activate
Execution
Open collector output (to GND)
Load
max. 12 V DC at 25 mA
Voltage drop condition 1
max. 1 V DC at 10 mA
Leakage current condition 0
> 50 mA
Table 32: Technical Information – GFI connection charging point 1 – GFI_Activate
Property
Value
Signal
GFI_Status
Execution
Contact input (to GND)
Load external driver/contact
max. 12 V DC at 10 mA
HIGH level
>= 1.5 V DC
Leakage current condition 0
> 50 µA
Table 33: Technical Information – GFI connection charging point 1 – GFI_Status
Property
Value
Signal
GFI_Welding
Execution
Contact input (to GND)
Load external driver/contact
max. 12 V DC at 10 mA
HIGH level
>= 1.5 V DC
Leakage current condition 0
> 50 µA
Table 34: Technical Information – GFI connection charging point 1 – GFI_Welding