Справочник Пользователя для innogy SE IEKA160

Скачать
Страница из 44
Technical Information 
LSX 
 
 
24 
4.3.14 
X15 
– 
GFI connection charging point 1 
GFI connection for charging point 1 takes place using socket X15. 
Property 
Value 
Socket 
Molex MicroFit 43045-0601 
Table 30: Technical Information – GFI connection charging point 1 
Property 
Value 
Signal 
GFI_Preset 
Execution 
Open collector output (to GND) 
Load 
max. 12 V DC at 25 mA 
Voltage drop condition 1 
max. 1 V DC at 10 mA 
Leakage current condition 0 
> 50 mA 
Table 31: Technical Information – GFI connection charging point 1 – GFI_Preset 
Property 
Value 
Signal 
GFI_Activate 
Execution 
Open collector output (to GND) 
Load 
max. 12 V DC at 25 mA 
Voltage drop condition 1 
max. 1 V DC at 10 mA 
Leakage current condition 0 
> 50 mA 
Table 32: Technical Information – GFI connection charging point 1 – GFI_Activate 
Property 
Value 
Signal 
GFI_Status 
Execution 
Contact input (to GND) 
Load external driver/contact 
max. 12 V DC at 10 mA 
HIGH level 
>= 1.5 V DC 
Leakage current condition 0 
> 50 µA 
Table 33: Technical Information – GFI connection charging point 1 – GFI_Status 
Property 
Value 
Signal 
GFI_Welding 
Execution 
Contact input (to GND) 
Load external driver/contact 
max. 12 V DC at 10 mA 
HIGH level 
>= 1.5 V DC 
Leakage current condition 0 
> 50 µA 
Table 34: Technical Information – GFI connection charging point 1 – GFI_Welding