Opticis M1-1POE-30 Manual De Usuario
M1-1P0E (Ver. 1.2)
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
Aug. 03, 2012
- 6 -
www.opticis.com
Reliability Test
Opticis utilizes three types of test criteria for a reduction of variability and a continuous improvement of
the process by its FEMA (Failure Mode and Effective Analysis) program.
1) Mechanical test (vibration, shock)
2) Temperature & humidity tests
3) EMC test (FCC class A and CE Verification)
Mechanical and Temperature & Humidity Test Data
Heading
Test
Conditions
Duration
Sample
Size
Failure
Remarks
Operating
Test
Operating at each
Temperature
(See Note)
* - 0 ~ 50 °C
(Interval: 10 °C)
30 Min
(Each
Temperature)
n =4
0
Note:
Visual
Test
on
the Display
Storage
Test
Low Temperature
* T
S
= -30 °C
96 HR
n=2
0
1. TS: Storage Temperature
High Temperature
* T
S
= 70 °C
96 HR
n=2
0
2. RH: Relative Humidity
High Humidity
High Temperature
* T
S
: 85 °C
* RH: 85%
96 HR
n=2
0
Mechanical
Test
Mechanical
Shock
* Pulse: 11 ms
* Peak level: 30 g
* Shock pulse: 3 times/Axis
-
n=2
0
Mechanical
Vibration
* Peak acceleration: 20 g
* Frequency: 20~2000 ㎐
* Sweep time: 30 Minutes
* 4 Times/Axis
-
n=2
0